OBJECTIVE To evaluate the efficacy of the use of retentive cup primary total hip replacement (THR) in high-dislocation risk subcapital fracture patients. METHODS During the years 2008 to 2012, 354 patients with displaced subcapital fracture were operated at our institute. The patients were selected to undergo primary constrained THR according to the following criteria: (1) a preinjury grade 4 or more on the Functional Independence Measure mobility item "5. Locomotion: walking/wheelchair" and grade 4 is defined as "4. Minimal assistance Requiring incidental hands-on help only" (patient performs >75% of the task) and (2) a disease leading to poor motor control. Exclusion criteria were normal muscular control and known infection of the involved joint. RESULTS Of the 354 patients, 87 fulfilled the inclusion criteria and underwent constrained total hip. Average age was 78 years with a female predominance (73%). Fifteen patients had prior hemiparesis, 19 had Parkinson disease, and 35 had generalized sarcopenia. Eighty-five patients had an uneventful recovery, with an average Hip Disability and Osteoarthritis Outcome Score (HOOS) of 76 ± 7 at 2 years. In 2 patients, the prostheses dislocated. In both cases, the dislocation was due to ring displacement and the inner head dislocated. One case was infected and the patient was treated by a Girdlestone procedure. In the other case, the prosthetic head was revised. The patient remained asymptomatic and at 4-year follow-up had an HOOS of 85. DISCUSSION It appears that constrained prosthesis is a suitable treatment for patients with poor muscular control having subcapital fractures. The functional results appear to be superior to those of bipolar arthroplasty and similar to the results of primary total hip arthroplasty while the dislocation risk is <3%. CONCLUSION Semielective total hip arthroplasty using a retentive cup liner appears to offer good functional results with a low dislocation rate in patients with poor muscular control.
منابع مشابه
Partial 2-Stage Revision in Chronic Hip Arthroplasty Infections: A Review
Background: Periprosthetic hip infections (PHIs) are troublesome complications of hip arthroplasties. The gold standard procedure for treating chronic PHI is a 2-stage approach. Recently, however, more conservative approaches have been developed to spare the osseointegrated components and avoid sequestra, bone loss, devascularization, and difficult reconstructions. The partial ...
متن کاملNo dislocations after primary hip arthroplasty with the dual mobility cup in displaced femoral neck fracture in patients with dementia. A one-year follow-up in 20 patients
PURPOSE The aim of this study was to describe the dislocation rates, reoperation rates and mortality 30 day and one year following THA with AVANTAGE® dual mobility cup among dementia patients with an acute displaced intracapsular femoral neck fracture. PATIENTS AND METHODS From 2010 to 2014 we identified 20 hip fracture patients with dementia, who have had total hip arthroplasty with the AVAN...
متن کاملAlumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study.
BACKGROUND Ceramic-on-ceramic couplings are attractive alternative bearing surfaces that have been reported to eliminate or reduce problems related to polyethylene wear debris. Disappointing experiences with alumina ceramic bearings in the past have led to many improvements in the manufacture and design of ceramic implants. The purpose of the present study was to report the results of contempor...
متن کاملCeramic-on-Ceramic Total Hip Arthroplasty: Minimum of Six-Year Follow-up Study
BACKGROUND This study examines the clinical and radiologic results of ceramic-on-ceramic total hip arthroplasties with regard to wear, osteolysis, and fracture of the ceramic after a minimum follow-up of six years. METHODS We evaluated the results of a consecutive series of 148 primary ceramic-on-ceramic total hip arthroplasties that had been performed between May 2001 and October 2005 in 142...
متن کامل[Analysis of the failures of a cemented constrained liner model in patients with a high dislocation risk].
OBJECTIVE To evaluate the short-term results of an ultra high molecular weight polyethylene retentive cup in patients at high risk of dislocation, either primary or revision surgery. MATERIAL AND METHOD Retrospective review of 38 cases in order to determine the rate of survival and failure analysis of a constrained cemented cup, with a mean follow-up of 27 months. We studied demographic data,...