Dialing Torque Preferences of People with Diabetes When Using Insulin Pens: A Pilot Study

نویسندگان

  • Arnd Friedrichs
  • Mario Schmitz
  • Stefan Kamlot
  • Steffen Adler
چکیده

INTRODUCTION Ergonomic dialing torque may enhance safety and comfort when setting doses with insulin pens. Limited data are available on the correlation of dialing torque and dialing comfort. METHODS Three studies were performed with SoloSTAR(®) (SS; Sanofi), FlexPen(®) (FP; Novo Nordisk), KwikPen(®) (KP; Eli Lilly) and FlexTouch(®) (FT; Novo Nordisk) pens. Dialing behavior was examined with 20 pen-experienced people with diabetes. Participants dialed up to the maximum dose and back down to "zero" with each pen. Hand and pen movements were recorded by video camera and rotational speeds and angles calculated for each pen. In a laboratory study, dialing torque was measured discontinuously at a speed of 120°/s, reflecting typical patient behavior. Sixteen pen-experienced people with diabetes participated in a pilot preference study. Using a Likert scale, subjective dialing comfort rankings and ratings were obtained for each pen type and matched to their dialing torque. SS, FP, KP, and FT1 were investigated at 0-20 U each and at 60-80 U for FT2. RESULTS SS was ranked most comfortable for up-dialing by 8 and down-dialing by 6 of the 16 participants, respectively; FP, 5 and 8; FT1, 2 and 1; and KP, 1 and 1. FT2 was ranked least comfortable by 12 and 10 participants. Comfort for up- and down-dialing was rated "very comfortable" for SS by 15 participants each, followed by FP (12 and 14), KP (10 each), and FT1 (9 and 7); FT2 was rated "less" or "not" comfortable by 10 and 11 people, respectively. CONCLUSION In this pilot study, subjective ratings of dialing comfort for different insulin pens by participants appear to concur with previous laboratory dialing torque study results. There appears to be a "torque comfort zone." Torques above 50 N mm reduced subjective handling comfort. Further, larger scale studies are needed to establish that dialing torque affects pen users' comfort.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Initial Experience and Evaluation of Reusable Insulin Pen Devices Among Patients with Diabetes in Emerging Countries

BACKGROUND Many individuals with type 2 diabetes in emerging countries are transitioning from vial-and-syringe insulin delivery to that of insulin pens (disposable or reusable). As with all insulin delivery methods, patient preferences and comfort are of utmost importance to optimize adherence to treatment. Patient-preferred characteristics for reusable insulin pens and barriers to appropriate ...

متن کامل

Comparison of clinically relevant technical attributes of five insulin injection pens.

BACKGROUND Insulin injection pens are the predominant devices for insulin delivery in Europe and Japan because of their ease of use and convenience. This study compared clinically relevant technical attributes of durable insulin pens that are important to people with diabetes, specifically functions relating to cartridge-fitting, dose-setting, and dose-delivery on NovoPen® 4, ClikStar®, HumaPen...

متن کامل

A comparison of dosing accuracy: visually impaired and sighted people using insulin pens.

BACKGROUND In the United States, 18% of people with diagnosed diabetes have visual impairment. Insulin pens are widely used by both blind and sighted people. However, major manufacturers include a disclaimer in the instructions warning against use by visually impaired people, without giving a rationale. Published studies neither support nor refute the disclaimer. METHOD The purpose of this st...

متن کامل

Ease of use of two reusable, half-unit increment dosing insulin pens by adult caregivers of children with type 1 diabetes: a randomized, crossover comparison.

Corresponding Author: Mayme Wong, Ph.D., Eli Lilly and Company, Lilly Corporate Center, Drop Code 2234, Indianapolis, IN 46285; email address [email protected] Insulin pens deliver accurate doses, which are important for children who require low doses and are at risk for hypoglycemia.1 Reusable insulin pens that deliver insulin in half-unit (U) increments include HumaPen® LuxuraTM HD (Eli Li...

متن کامل

Establishment of Reference Interval for Homeostasis Model Assessment of Insulin Resistance in Healthy Adult Males: a Pilot Study in Alexandria Governorate, Egypt

Abstract Objective: Homeostasis model assessment of insulin resistance (HOMA-IR) is a simple and practical method for estimation of insulin resistance (IR), but a reliable reference interval (RI) of HOMA-IR is needed to deduce the threshold level to define IR. This RI has been controversial in different populations and even more divergent when considering factors like age, gender and body mass...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2015