Test-retest variability of frequency-doubling perimetry and conventional perimetry in glaucoma patients and normal subjects.

نویسندگان

  • B C Chauhan
  • C A Johnson
چکیده

PURPOSE To compare the test-retest variability characteristics of frequency-doubling perimetry, a new perimetric test, with those of conventional perimetry in glaucoma patients and normal control subjects. METHODS The study sample contained 64 patients and 47 normal subjects aged 66.16+/-11.86 and 64.26+/-7.99 years (mean +/- SD), respectively. All subjects underwent frequency-doubling perimetry (using the threshold mode) and conventional perimetry (using program 30-2 of the Humphrey Field Analyzer; Humphrey Instruments, San Leandro, CA) in one randomly selected eye. Each test was repeated at 1-week intervals for five tests with each technique over 4 weeks. Empirical 5th and 95th percentiles of the distribution of threshold deviations at retest were determined for all combinations of single tests and mean of two tests, stratified by threshold deviation. The influence of visual field eccentricity and overall visual field loss on variability also were examined. RESULTS Mean test time with frequency-doubling perimetry in patients and normal control subjects was 5.90 and 5.25 minutes, respectively, and with conventional perimetry was 17.20 and 14.01 minutes, respectively. In patients, there was a significant correlation between the results of the two techniques, in the full field and in quadrants, whereas in normal subjects there was no such correlation. In patients, the retest variability of conventional perimetry in locations with 20-dB loss was 120% (single tests) and 127% (mean tests) higher compared with that in locations with 0-dB loss. Comparative figures for frequency-doubling perimetry were 40% and 47%, respectively. Variability also increased more with threshold deviation in normal subjects tested with conventional perimetry. In both patients and normal subjects, variability increased with visual field eccentricity in conventional perimetry, but not in frequency-doubling perimetry. Both techniques showed an increase in variability with overall visual field damage. CONCLUSIONS Frequency-doubling perimetry has different test-retest variability characteristics than conventional perimetry and may have potential for monitoring glaucomatous field damage.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variability components of standard automated perimetry and frequency-doubling technology perimetry.

PURPOSE To evaluate and compare intra- and intertest variability components for both standard automated perimetry (SAP) and frequency-doubling technology (FDT) perimetry in a small group of normal individuals and patients with glaucoma. METHODS The method of constant stimuli (MOCS) was used to examine matched test locations with both SAP and FDT perimetry stimuli in a group of eight normal in...

متن کامل

Performance of efficient test procedures for frequency-doubling technology perimetry in normal and glaucomatous eyes.

PURPOSE To validate the clinical performance of two new efficient threshold-estimation procedures for frequency-doubling technology (FDT) perimetry in both visually normal individuals and patients with glaucomatous visual field loss. METHODS Forty-one normal subjects (mean age, 48.3 +/- 11.6 years) and 50 patients with glaucomatous visual field loss (mean age, 72.7 +/- 10.0 years) were tested...

متن کامل

Learning effect of humphrey matrix frequency doubling technology perimetry in patients with ocular hypertension.

AIM To evaluate the learning effect of Frequency Doubling Technology (FDT) perimetry using the Humphrey Matrix-FDT perimetry (Matrix) 24-2 full-threshold program on patients with ocular hypertension experienced with standard automated perimetry. METHODS Twenty-four patients with ocular hypertension underwent 5 full-threshold Matrix tests at intervals of 5+/-2 days. Learning effect was defined...

متن کامل

Choice of Stimulus Range and Size Can Reduce Test-Retest Variability in Glaucomatous Visual Field Defects.

PURPOSE To develop guidelines for engineering perimetric stimuli to reduce test-retest variability in glaucomatous defects. METHODS Perimetric testing was performed on one eye for 62 patients with glaucoma and 41 age-similar controls on size III and frequency-doubling perimetry and three custom tests with Gaussian blob and Gabor sinusoid stimuli. Stimulus range was controlled by values for ce...

متن کامل

Screening for glaucoma with frequency-doubling technology and Damato campimetry.

OBJECTIVE To assess frequency-doubling technology (FDT) perimetry (Humphrey Systems, San Leandro, Calif) and Damato campimetry (Precision Vision, Villa Park, Ill) for detecting glaucoma in a public glaucoma screening. METHODS A 2-day public glaucoma screening was held at 2 different institutions. Each subject underwent 2 visual field screening tests (Damato campimetry and FDT perimetry in scr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 40 3  شماره 

صفحات  -

تاریخ انتشار 1999