Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study)
نویسندگان
چکیده
BACKGROUND Angulated implants may result in inaccurate impressions, and the impression technique may affect the accuracy of the definitive cast. This study was designed to compare the dimensional accuracy of casts obtained from three impression techniques for three definitive lower casts with implants at different angulations. METHODS Three Osseolink implants were placed in three reference models with different angles (parallel, 15° and 30°). Impressions of each model were made with three techniques (n = 10 per group): indirect, unsplinted direct, and acrylic resin-splinted direct technique. Impressions were poured with type IV dental stone. Inter-implant distances were measured for casts using a coordinate measuring machine, and the deviations from the reference models (Δr) were calculated. Data were analyzed using one-way ANOVA followed by post hoc tests to detect significance between groups (α = 0.05). RESULTS This study showed that the deviations in micrometers from the reference model were the least for acrylic resin-splinted direct technique (Δr1 = 49.96, Δr2 = 50.36) versus indirect (Δr1 = 93.8, Δr2 = 90.9) and unsplinted direct techniques ((Δr1 = 67.07, Δr2 = 68.66) in 30° angulated implant situation (p value < 0.0001* for both Δr1 and Δr2). In 15° angulated implants, both the acrylic resin-splinted direct (Δr1 = 44.64, Δr2 = 45.58) and unsplinted direct techniques (Δr1 = 47.39, Δr2 = 55.28) were more accurate than indirect technique (Δr1 = 64.8, Δr2 = 68.3) (p value < 0.0001* for both Δr1 and Δr2). While in parallel condition, no difference was found between all three techniques (p value = 0.085, 0.056 for Δr1 and Δr2, respectively). CONCLUSIONS The impression technique affected the accuracy of definitive casts. The acrylic resin splinted direct technique produced the most accurate casts, followed by direct unsplinted and indirect techniques. Furthermore, implant angulation affected the impression accuracy. When implant angulation increased from parallel implants to 30°, the forces of deformation increased, which resulted in increased distortion.
منابع مشابه
Accuracy of Digital vs Conventional Implant Impression Approach: A Three-Dimensional Comparative In Vitro Analysis.
PURPOSE To assess the three-dimensional (3D) accuracy and clinical acceptability of implant definitive casts fabricated using a digital impression approach and to compare the results with those of a conventional impression method in a partially edentulous condition. MATERIALS AND METHODS A mandibular reference model was fabricated with implants in the first premolar and molar positions to sim...
متن کاملEffect of splinted and nonsplinted impression techniques on the accuracy of fit of fixed implant prostheses in edentulous patients: a comparative study.
PURPOSE The effect of different implant impression techniques on the accuracy of casts has been investigated mostly in vitro, and clinically relevant evidence is scarce. The purpose of this study was to investigate the effect of implant impression techniques--specifically, splinted versus nonsplinted--on the accuracy of fit of fixed implant prostheses in edentulous patients. MATERIALS AND MET...
متن کاملAccuracy of two impression techniques with angulated implants.
STATEMENT OF PROBLEM Accurate recording of implant locations is required so that definitive restorations are properly supported and do not place additional stress on the implants. Angulated implants may result in inaccurate impressions, and the impression technique may affect the accuracy of the definitive cast. PURPOSE The purpose of this study was to determine the effect the combined intera...
متن کاملComparison of implant cast accuracy of multiple implant impression technique with different splinting materials: An in vitro study
INTRODUCTION An accurate and passive fit of implant framework prosthesis, as well as the successful surgical operation is suggested as one of the critical requirements for long-term implant success. OBJECTIVE The purpose of this in vitro study was to evaluate the accuracy of the master cast using open tray impression technique with conventional and novel splinting materials. METHODOLOGY A m...
متن کاملDimensional accuracy of three impression materials by one-step and two-step impression techniques: An in vitro study
Introduction: An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. Methods: In this study, 20 impressions were fabricated for each Vinyl siloxane ether (Identium), condensation silicone (Speedex), and a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -