Aperture Proximity Effects in High Heat Flux Sensors Calibration

نویسندگان

  • A. V. Murthy
  • B. K. Tsai
  • R. D. Saunders
چکیده

In the transfer calibration of heat flux sensors, a correction for the irradiance distribution across the sensing area may be required when the sensing areas of the reference and test sensors are different. A method to calculate this correction using well-known equations for the configuration factors is presented. Also, estimates of the correction for test conditions corresponding to the transfer calibration technique in use at the National Institute of Standards and Technology are given.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration of High Heat Flux Sensors at NIST

An ongoing program at the National Institute of Standards and Technology (NIST) is aimed at improving and standardizing heat-flux sensor calibration methods. The current calibration needs of U.S. science and industry exceed the current NIST capability of 40 kW/m2 irradiance. In achieving this goal, as well as meeting lower-level non-radiative heat flux calibration needs of science and industry,...

متن کامل

Transfer Calibration Validation Tests on a Heat Flux Sensor in the 51 mm High-Temperature Blackbody

Facilities and techniques to characterize heat flux sensors are under development at the National Institute of Standards and Technology. As a part of this effort, a large aperture high-temperature blackbody was commissioned recently. The graphite tube blackbody, heated electrically, has a cavity diameter of 51 mm and can operate up to a maximum temperature of 2773 K. A closed-loop cooling syste...

متن کامل

Comparative Calibration of Heat Flux Sensors in Two Blackbody Facilities

National Institute of Standards and Technology, Gaithersburg, MD 20899-0001 This paper presents the results of heat flux sensor calibrations in two blackbody facilities: the 25 mm variable temperature blackbody (VTBB) primary facility and a recently developed 51 mm aperture spherical blackbody (SPBB) facility. Three Schmidt-Boelter gages and a Gardon gage were calibrated with reference to an el...

متن کامل

Radiative Calibration of Heat-Flux Sensors at NIST: Facilities and Techniques

We present an overview of the National Institute of Standards and Technology high temperature blackbodies, both in operation and in development, suitable for heat-flux sensor calibration. Typical results of calibrations using the transfer technique in the 25 mm Variable-Temperature Blackbody are presented to demonstrate the long-term repeatability of the calibration technique. A comparative stu...

متن کامل

A Summary of Heat-Flux Sensor Calibration Data

This paper presents a statistical evaluation of the responsivity data on a number of heat-flux sensors, calibrated using an electrical substitution radiometer as a transfer standard up to 5 W·cm(-2). The sensors, furnished by the customers, were of circular-foil or thermopile type. Comparison of the NIST and the customer measured responsivity values showed that the measurements agree within 3 %...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 103  شماره 

صفحات  -

تاریخ انتشار 1998