Analytical evaluation of i-STAT Portable Clinical Analyzer and use by nonlaboratory health-care professionals.
نویسندگان
چکیده
We evaluated the performance of the i-STAT Portable Clinical Analyzer, a hand-held instrument that, with its current cartridge, analyzes for electrolytes, urea nitrogen, glucose, and hematocrit in approximately 60 microL of whole blood in approximately 90 s. Accuracy, imprecision, and linearity studies were performed with aqueous controls and standards and by split-sample analysis. Intrarun imprecision (CV) ranged from 0.34% to 3.97%. Total imprecision over a 2-month period ranged from 0.42% to 4.83%, with urea nitrogen and glucose analyses generating the higher values. Patients' results from the Portable Clinical Analyzer correlated well with those obtained for whole blood or plasma by the Nova Stat Profile 5, the Beckman Synchron CX3, or the Technicon H1 Hematology Analyzer, with Sylx values < 0.2 mmol/L for potassium; < 1.5 mmol/L for sodium, glucose, and urea nitrogen; < 2.4 mmol/L for chloride, and < 2.4% for hematocrit. We also ascertained imprecision and accuracy of the system placed in a cardiothoracic intensive-care unit and operated by nurses. There were no significant differences in either the imprecision or accuracy of the system in this setting. We conclude that operator technique is not a factor in the analytical performance of the system and that it can be used by nonlaboratorians with a high degree of confidence that reliable results will be obtained.
منابع مشابه
Evaluation of the i-STAT portable clinical analyzer in chickens (Gallus gallus).
The i-STAT portable clinical analyzer (PCA) was evaluated for performance in avian species. With the EG7+ cartridge, which provided results for hydrogen ion concentration, oxygen tension, carbon dioxide tension, sodium, potassium, ionized calcium, hematocrit, and various calculated parameters, analytical accuracy and precision were tested by comparing obtained values to those of established tra...
متن کاملEvaluation of the i-STAT Portable Clinical Analyzer for point-of-care blood testing in the intensive care units of a university children's hospital.
We evaluated the analytical performance of the i-STAT Portable Clinical Analyzer (PCA), a point-of-care testing system consisting of a hand-held analyzer and single-use cartridges that measure different panels of electrolytes, metabolites, blood gases, and hematocrit in 65-100 microl of blood. Our objective was to determine whether PCA measurements at the bedside of patients in the neonatal and...
متن کاملEvaluation of a novel point-of-care system, the i-STAT portable clinical analyzer.
We evaluated a novel system designed for rapid, point-of-care measurement of sodium, potassium, chloride, urea nitrogen, glucose, and hematocrit. The i-STAT Portable Clinical Analyzer (PCA) system is composed of a hand-held analyzer and disposable cartridges. Sample analysis takes place in the cartridge, which contains a series of thin-film electrodes microfabricated on silicon chips. The PCA w...
متن کاملEvaluation of the i-STAT portable point-of-care analyzer for determination of blood gases and acid-base status in newborn calves.
OBJECTIVE To validate the i-STAT, a portable hand-held analyzer that allows point-of-care measurement of blood gases, acid-base, lactate, and other blood variables in food animal practice for analysis of blood samples of newborn calves. DESIGN Prospective observational study. SETTING University teaching hospital. MEASUREMENTS AND MAIN RESULTS A total of 271 venous blood samples were analy...
متن کاملBlood gas, oxygen saturation, pH, and lactate values in elasmobranch blood measured with a commercially available portable clinical analyzer and standard laboratory instruments.
Blood gas, pH, and lactate data are often used to assess the physiological status and health of fish and can often be most valuable when blood samples are analyzed immediately after collection. Portable clinical analyzers allow these measurements to be made easily in the field. However, these instruments are designed for clinical use and thus process samples at 37 degrees C. A few studies have ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 39 6 شماره
صفحات -
تاریخ انتشار 1993