Computed Tomography Colonography Phantom: Construction, Validation and Literature Review
نویسندگان
چکیده
BACKGROUND Several dedicated computed tomography (CT) colonography phantoms have been described previously. OBJECTIVES To compare their pros and cons and describe the construction of a dedicated phantom that can be easily manufactured. MATERIALS AND METHODS We found 15 different phantom designs by literature search and compared their advantages and disadvantages based on their description and images. We tested various materials for density and mechanical properties and constructed a phantom from polypropylene pipes (30 mm and 50 mm in diameter, 52 cm in length). Haustral folds were created by heat shaping and 39 intermediate sessile polyps with a target size of 6-10 mm and two flat lesions were created from silicone. Nine polyps were attached to a fold. The model was placed in a 30-cm barrel filled with water to simulate attenuation of human body. Attenuation of polyps was compared to intermediate polyps found in patients. RESULTS None of the earlier colonic phantoms found in the literature incorporated all the properties that would ensure both reproducibility and validity of the model (including a rigid wall, density of the wall and polyps similar to human colon, at least two levels of distension and durability). In the present phantom, the average size of sessile polyps was 8.6 ± 0.9 mm and their density was 53 ± 24 HU. We found no significant difference in polyp density between simulated polyps in the phantom and polyps in human subjects (P = 0.70). All polyps, with the exception of one flat lesion, were detected by computer aided detection. CONCLUSION We constructed and validated a CT colonography phantom with correct density allowing performance of reproducible experiments.
منابع مشابه
Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners
Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...
متن کاملDesign and Construction of an Affordable Phantom for Electron Density Measurement and Linearity Tests of Computed Tomography Systems
Introduction: The performance of computed tomography is routinely checked using phantoms, which are known as important diagnostic imaging tools. Depending upon the aim of the study, different phantoms are designed, while trying to satisfy certain levels of diversities in their application. Material and Methods: The present study describes the...
متن کاملQuantitative Computed Tomography (QCT) derived Bone Mineral Density (BMD) in finite element studies: a review of the literature
BACKGROUND Finite element modeling of human bone provides a powerful tool to evaluate a wide variety of outcomes in a highly repeatable and parametric manner. These models are most often derived from computed tomography data, with mechanical properties related to bone mineral density (BMD) from the x-ray energy attenuation provided from this data. To increase accuracy, many researchers report t...
متن کاملDevelopment of a Liver Phantom Based on Computed Tomography Images for Dosimetric Purpose
Introduction: The present study was conducted with the aim of designing a liver phantom for dosimetry. To benchmark the results obtained by the developed liver phantom, another method was applied for the dosimetry of a real liver tissue using imaging. Materials and Methods: For the purpose of the study, a real liver tissue was converted into a phantom based on thegram-molecular weight of the co...
متن کامل[Computed tomography colonography image assessment using colon phantom-effects of reconstructed slice thickness].
Computed tomography colonography (CTC) is a robust and reliable imaging test of the colon. Recent studies show good sensitivity for the identification of nonpolypoid (flat) lesions as well. The purpose of this study was to determine the accuracy and reproducibility of a volume-rendering (VR) and virtual gross pathology (VGP) technique for detecting a polypoid lesion phantom by varying slice thi...