Bladder cancer: detection and image quality compared among iShim, RESOLVE, and ss-EPI diffusion-weighted MR imaging with high b value at 3.0 T MRI
نویسندگان
چکیده
To compare the detection of bladder neoplasms and image quality among the diffusion-weighted imaging (DWI) acquired by the prototype single-shot echo-planar-imaging (ss-EPI) sequence for integrated slice-specific dynamic shimming (iShim), readout segmentation of long variable echo trains (RESOLVE) and conventional ss-EPI sequences.Around 63 patients with 77 bladder lesions were enrolled. The MR protocol included T1WI, T2WI and 3 types of DWI. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of each DWI for the detection of bladder tumor were computed. The subjective scores of imaging quality, diagnostic confidence, and detection of tumors of stage T2 or greater were recorded. The contrast-to-noise ratio (CNR), signal intensity ratios, and apparent diffusion coefficient (ADC) values were measured. The univariate analysis of variance technique, the Friedman test, and Bland-Altman plots were used in the statistical analysis. Observer performance of tumor T stage was tested using receiver operating characteristic (ROC) curve analysis.The sensitivity, NPV, and accuracy of iShim (92.75%; 61.54%; 93.51%) for detection of bladder tumor were superior to those of RESOLVE (84.06%; 42.11%; 85.71%) and ss-EPI (86.96%; 47.06%; 88.31%). All qualitative scores of iShim were higher than RESOLVE (all P < .05) and ss-EPI (all P < .05). The CNR, signal intensity ratios between bladder lesion and urine, lesion, and submucosal stalk (or nearby normal bladder wall), and between distal normal bladder wall and urine of iShim (39.84 ± 12.11, 2.40 ± 0.60, 1.98 ± 0.43, 1.28 ± 0.16) were higher than RESOLVE (16.97 ± 7.08, 1.62 ± 0.41, 1.52 ± 0.42, 1.15 ± 0.29, all P < .05) and ss-EPI (27.89 ± 9.65, 1.66 ± 0.46, 1.57 ± 0.50, 0.99 ± 0.22, all P < .05). No significant difference of ADC values were found for iShim and RESOLVE (P=0.46), iShim, and ss-EPI (P = 0.97), RESOLVE and ss-EPI (P = .48). The Az value for the detection of tumors of stage T2 or greater was slightly higher with the iShim DWI sequence (0.89) than with the RESOLVE (0.87, P = 0.72) or ss-EPI (0.85, P = .38) sequence.The iShim DWI has relatively better detection of bladder tumor and image quality without significant ADC value difference.
منابع مشابه
Signal Intensity of High B-value Diffusion-weighted Imaging for the Detection of Prostate Cancer
Background: Diffusion-weighted imaging (DWI) is a main component of multiparametric MRI for prostate cancer detection. Recently, high b value DWI has gained more attention because of its capability for tumor characterization. Objective: To assess based on histopathological findings of transrectal ultrasound (TRUS)-guided prostate biopsy as a reference, an...
متن کاملReadout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality
OBJECTIVE The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. MATERIALS AND METHODS Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of ...
متن کاملبررسی ارزش Diffusion Weighted Imaging در تصاویر MRI برای تشخیص سرطان پروستات
Background: Prostate cancer is the third leading cause of death and is the most common cause of cancer in elderly men. Regarding to the low accuracy of screening methods such as prostate-specific antigen (PSA), Digital Rectal Examination (DRE) and trans rectal ultrasound (TRUS) in detection and localization of tumor, Magnetic Resonance Imaging (MRI) and Diffusion Weighted Imaging (DWI) attracte...
متن کاملStudy of the reduced field-of-view diffusion-weighted imaging of the breast.
BACKGROUND This study aimed to compare the imaging quality, apparent diffusion coefficient (ADC) values, and application values between reduced field-of-view diffusion-weighted imaging (rFOV DWI) and single-shot echo-planar-imaging diffusion-weighted imaging (SS-EPI DWI) of breast tissue. PATIENTS AND METHODS For 87 cases (75 with normal breast tissue, 12 with mammary cancer), breasts were sc...
متن کاملApplications of diffusion weighted imaging in detection of radiating pain to lower extremities
Introduction: To examine the hypothesis that diffusion weighted imaging (DWI) in lumbosacral region could reveal sciatic nerve course swelling that lead to lower extremity pain. The aim of present article was to find and evaluate the diffusion weighted coefficients (b-values) for scrutinizing sciatic nerve tract changes in lumbosacral region. Materials and methods: Lumbar area was imaged in 30...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 96 شماره
صفحات -
تاریخ انتشار 2017