Detection of coronary artery stenosis with whole-heart coronary magnetic resonance angiography.

نویسندگان

  • Hajime Sakuma
  • Yasutaka Ichikawa
  • Shuji Chino
  • Tadanori Hirano
  • Katsutoshi Makino
  • Kan Takeda
چکیده

OBJECTIVES We sought to determine the diagnostic performance of whole-heart coronary magnetic resonance (MR) angiography for detecting significant coronary artery disease. BACKGROUND The accuracy of whole-heart coronary MR angiography has not been determined in a large number of patients. METHODS Three-dimensional coronary MR angiograms covering the entire heart were obtained during free breathing in 131 patients. Images were acquired during a patient-specific time window in the cardiac cycle with minimal motion of the coronary artery. Significant coronary artery disease was defined on X-ray coronary angiography as a diameter reduction of > or =50% in coronary arteries with a reference diameter of > or =2 mm. RESULTS The acquisition of MR angiography was completed in 113 (86%) of 131 patients, with an imaging time averaged at 12.9 +/- 4.3 min. On a patient-based analysis, the sensitivity, specificity, positive and negative predictive value, and accuracy of MR angiography were 82% (95% confidence interval [CI] 69% to 91%), 90% (95% CI 79% to 96%), 88% (95% CI 74% to 95%), 86% (95% CI 75% to 93%), and 87% (95% CI 79% to 92%), respectively. These values in the individual segments were 78% (95% CI 68% to 85%), 96% (95% CI 95% to 97%), 69% (95% CI 60% to 77%), 98% (95% CI 96% to 98%), and 94% (95% CI 96% to 96%). CONCLUSIONS Whole-heart coronary MR angiography allows for noninvasive detection of significant narrowing in coronary arterial segments with a diameter of > or =2 mm with moderate sensitivity and high specificity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated coronary artery tracking in contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0T

Background Contrast-enhanced whole heart coronary Magnetic Resonance Angiography (MRA) at 3.0 Tesla (T) allows noninvasive detection of obstructive stenoses. Automated vessel segmentation and tracking of centerlines is important for quantitative measurement of stenosis, but remains challenging for coronary MRA. We aimed to develop and validate automated coronary artery segmentation from contras...

متن کامل

Relationship between Late Gadolinium Enhancement Extent in Cardiac Magnetic Resonance Imaging and Severity of Coronary Artery Disease in Old Myocardial Infarction

Purpose: To assess the relationship between the severity of coronary arteries involvement and the extent and pattern of myocardial scars in Cardiac Magnetic Resonance of patients with history of remote myocardial infarction. Materials and Methods: The Cardiac Magnetic Resonance images of sixty patients with history of remote ST segment or non-ST segment elevation myocardial infarction were ...

متن کامل

Feasibility and Diagnostic Accuracy of Whole Heart Coronary MR Angiography Using Free-Breathing 3D Balanced Turbo-Field-Echo with SENSE and the Half-Fourier Acquisition Technique

OBJECTIVE We wanted to assess the feasibility and diagnostic accuracy of whole heart coronary magnetic resonance angiography (MRA) with using 3D balanced turbo-field-echo (b-TFE) with SENSE and the half-Fourier acquisition technique for identifying stenoses of the coronary artery. MATERIALS AND METHODS Twenty-one patients who underwent both whole heart coronary MRA examinations and convention...

متن کامل

Assessment of coronary arteries with total study time of less than 30 minutes by using whole-heart coronary MR angiography.

This study had institutional review board approval, and all patients gave informed consent. The purpose of this study was to prospectively evaluate the use of whole-heart three-dimensional (3D) coronary magnetic resonance (MR) angiography in patients suspected of having coronary artery disease. Whole-heart coronary MR angiography was performed in 39 patients (30 men and nine women; mean age, 63...

متن کامل

Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0-T: a comparative study with X-ray angiography in a single center.

OBJECTIVES The purpose of this study was to prospectively evaluate the diagnostic performance of 3.0-T contrast-enhanced whole-heart coronary magnetic resonance angiography (CMRA) in patients with suspected coronary artery disease (CAD). BACKGROUND A slow-infusion, contrast-enhanced whole-heart CMRA approach has recently been developed at 3.0-T. The accuracy of this technique has not yet been...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 48 10  شماره 

صفحات  -

تاریخ انتشار 2006