Evaluation of radiation dose and image quality following changes to tube potential (kVp) in conventional paediatric chest radiography

نویسندگان

  • S Ramanaidu
  • RB Sta Maria
  • KH Ng
  • J George
  • G Kumar
چکیده

PURPOSE A study of radiation dose and image quality following changes to the tube potential (kVp) in paediatric chest radiography. MATERIALS AND METHOD A total of 109 patients ranging from 1 month to 15 years were included in two phases of the study. Phase 1 investigated the range of entrance surface air kerma (ESAK) values received from patients exposed to the existing exposure factors. In the second phase, new exposure factors using recommended values of tube potential (kVp) with reduced mAs were used. ESAK values were measured using thermoluminescent dosemeters (TLDs). Image quality in both phases was evaluated using image quality criteria proposed by the Council of the European Communities (CEC). Results of both techniques were analysed for any differences. RESULTS The overall mean ESAK before the changes was 0.22 mGy (range: 0.05-0.43) Following changes in tube potential, the overall mean reduced to 0.15 mGy (range: 0.03-0.38), a significant reduction by 34%. The interquartile range was reduced from 45% to 40%. However, doses to those below a year in age still remained high. Assessment of image quality was found to have no significant differences as far as the two techniques used were concerned. However, higher image scores were achieved using higher kVps. CONCLUSION Significant dose reduction was achieved through appropriate changes in tube potential and reduction of mAs without any loss in image quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Evaluation of Conventional X-ray Exposure Parameters Including Tube Voltage and Exposure Time in Private and Governmental Hospitals of Lorestan Province, Iran

Introduction In radiography, dose and image quality are dependent on radiographic parameters. The problem is caused from incorrect use of radiography equipment and from the radiation exposure to patients much more than required. Therefore, the aim of this study was to implement a quality-control program to detect changes in exposure parameters, which may affect diagnosis or patient radiation do...

متن کامل

Local-Reference Patient Dose Evaluation in Conventional Radiography Examinations in Mazandaran, Iran

Background:The most efficient application of ionizing radiation is serving medical purposes and using this radiation has caused people to learn that artificial sources of radiation exposure among these resources can be of highest exposure rate.  Objective: The present study is aimed at initially establishing a baseline for local-reference dose level in Mazandaran, Iran in 12 projections of the...

متن کامل

Effects of Kilovoltage on Image Quality and Entrance Surface Dose in Lumbar Spine Digital Radiography

Introduction: Digital radiography possesses a wide dynamic range and has a major advantage in producing an acceptable image of diagnostic value even though overexposure occurs. Lumbar spine (LS) radiography is the most common examinations that gives high radiation dose to patients and accounts for the highest collective population dose of any conventional radiographic ...

متن کامل

A Phantom Study for the Optimization of Image Quality and Radiation Dose for Common Radiographic Examinations in Digital Radiography

Introduction: Phantom studies facilitate the implementation of radiation dose surveillance as a function of radiographic technical parameters for minimizing patient radiation dose. The evidence of such investigations can then be used to evaluate technical parameters used in the radiographic procedures to reduce radiation dose without compromising the image quality. Material and Methods: This ex...

متن کامل

Evaluation of the Influence of Exposure Index on Image Quality and Radiation Dose

Introduction: The introduction of digital radiography has led to a significant problem in terms of dose creep. To address this problem, manufacturers have established a set of exposure indicators (EI) as a feedback mechanism to safeguard against overexposure. The EI is the measure of incident exposure to the detector that is directly proportional to the signal-to-noise...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2006