A new anchor augmentation technique with a cancellous screw in osteoporotic rotator cuff repair: an in vitro biomechanical study on sheep humerus specimens.

نویسندگان

  • Vedat Uruc
  • Raif Ozden
  • Yunus Dogramacı
  • Aydıner Kalacı
  • Hasan Hallaceli
  • Fatih Küçükdurmaz
چکیده

PURPOSE The aim of this study was to test a simple technique to augment the pullout resistance of an anchor in an over-drilled sheep humerus model. METHODS Sixty-four paired sheep humeri were harvested from 32 male sheep aged 18 months. Specimens were divided into an augmented group and non-augmented group. FASTIN RC 5-mm titanium screw anchors (DePuy Mitek, Raynham, MA) double loaded with suture material (braided polyester, nonabsorbable USP No. 2) were used in both groups. Osteoporosis was simulated by over-drilling with a 4.5-mm drill. Augmentation was performed by fixing 1 of the sutures 1.5 cm inferior to the anchor insertion site with a washer screw. This was followed by a pull-to-failure test at 50 mm/min. The ultimate load (the highest value of strength before anchor pullout) was recorded. A paired t test was used to compare the biomechanical properties of the augmented and non-augmented groups. RESULTS In all specimens the failure mode was pullout of the anchor. The ultimate failure loads were statistically significantly higher in the augmented group (P < .0001). The mean pullout strength was 121.1 ± 10.17 N in the non-augmented group and 176.1 ± 10.34 N in the augmented group. CONCLUSIONS The described augmentation technique, which is achieved by inferior-lateral fixation of 1 of the sutures of the double-loaded anchor to a fully threaded 6.5-mm cancellous screw with a washer, significantly increases the ultimate failure loads in the over-drilled sheep humerus model. CLINICAL RELEVANCE Our technique is simple, safe, and inexpensive. It can be easily used in all osteoporotic patients and will contribute to the reduction of anchor failure. This technique might be difficult to apply arthroscopically. Cannulated smaller screws would probably be more practical for arthroscopic use. Further clinical studies are needed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical evaluation of a new technique for rotator cuff repair.

BACKGROUND In recent studies, investigators have used a cyclic loading model to investigate the efficacy of rotator cuff fixation modalities. HYPOTHESIS A bioabsorbable poly-D-lactic acid screw and toothed washer implant will provide more stable fixation of rotator cuff repairs than standard suture anchor techniques. STUDY DESIGN Controlled laboratory study. METHODS Forty bovine shoulders...

متن کامل

Biomechanical effect of rotator cuff augmentation with an acellular dermal matrix graft: a cadaver study.

BACKGROUND Acellular human dermal matrix grafts (Graftjacket; Wright Medical Technology, Arlington, TN, USA) are used clinically for rotator cuff augmentation without a detailed understanding of their biomechanical effects. The purpose of this study was to evaluate the effect of augmentation with dermal grafts on the biomechanical effects of rotator cuff repairs. METHODS Nine matched pairs of...

متن کامل

A biodegradable button to augment suture attachment in rotator cuff repair.

Recent experimental studies suggest that the use of suture anchors for rotator cuff tear (RCT) repair transfers the "weak link" to the suture-tendon interface where failure occurs as the sutures cut through the tendon. The purpose of this study was to evaluate the effect of using a suture augmentation button on the fixation strength of rotator cuff tendon repair. A 1.5 cm by 2 cm defect was cre...

متن کامل

Suture anchor fixation strength with or without augmentation in osteopenic and severely osteoporotic bones in rotator cuff repair: a biomechanical study on polyurethane foam model

BACKGROUND The purpose of the present study was to compare the results of various types of anchor applications with or without augmentation in both osteopenic and severely osteoporotic bone models. METHODS Two different types of suture anchors were tested in severely osteoporotic (SOP) and osteopenic polyurethane (PU) foam blocks using an established protocol. An Instron machine applied stati...

متن کامل

Preliminary Results of a Consecutive Series of Large & Massive Rotator Cuff Tears Treated with Arthroscopic Rotator Cuff Repairs Augmented with Extracellular Matrix

 Background: Recurrence rate of rotator cuff tears is still high despite the improvements of surgical techniques, materials used and a better knowledge of the healing process of the rotator cuff tendons. Large to massive rotator cuff tears are particularly associated with a high failure rate, especially in elderly. Augmentation of rotator cuff repairs with extracellular matrix or synthetic patc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association

دوره 30 1  شماره 

صفحات  -

تاریخ انتشار 2014