RF Shimming Capabilities at 9.4 Tesla using a 16-channel Dual-Row Array
نویسندگان
چکیده
Fig.2: Simulated field maps along with inslice B1 field statistics and SEE. B1 in homogeneous solutions is scaled by the indicated factors for better visualization. RF Shimming Capabilities at 9.4 Tesla using a 16-channel Dual-Row Array Jens Hoffmann, G. Shajan, Klaus Scheffler, and Rolf Pohmann High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tuebingen, Baden-Wuerttemberg, Germany, Department for Biomedical Magnetic Resonance, University of Tuebingen, Tuebingen, Baden-Wuerttemberg, Germany
منابع مشابه
Human Brain Imaging at 9.4 Tesla Using a Combination of Traveling Wave Excitation with a 15-channel Receive-only Array
Introduction The combination of a circularly polarized (CP) volume coil for spin excitation with a multi-channel receive-only array is a successful setup for routine human brain imaging at 7 Tesla. For reception, the use of multiple surface coils is important for a high SNR and for the utilization of parallel imaging techniques. For transmission, the main strength of the CP coil is the reasonab...
متن کاملFeasibility of high-dose dobutamine stress SSFP cine MRI at 3 Tesla with patient adaptive local RF shimming using dual-source RF transmission: initial results
PURPOSE To investigate the feasibility of high-dose dobutamine stress (HDDS) imaging using SSFP sequences at 3 T employing patient-adaptive local RF-shimming using a dual-source RF transmission system. MATERIALS AND METHODS 13 Patients underwent a HDDS protocol on a 3 T MRI scanner (Achieva 3.0T-TX, Philips Healthcare), equipped with a dual-source RF transmission system. SSFP cine sequences u...
متن کاملA Specialized Multi-Transmit Head Coil for High Resolution fMRI of the Human Visual Cortex at 7T
PURPOSE To design, construct and validate radiofrequency (RF) transmit and receive phased array coils for high-resolution visual cortex imaging at 7 Tesla. METHODS A 4 channel transmit and 16 channel receive array was constructed on a conformal polycarbonate former. Transmit field efficiency and homogeneity were simulated and validated, along with the Specific Absorption Rate, using [Formula:...
متن کاملImprovement in B1+ Homogeneity and Average Flip Angle Using Dual-Source Parallel RF Excitation for Cardiac MRI in Swine Hearts
Cardiac MRI may benefit from increased polarization at high magnetic field strength of 3 Tesla but is challenged by increased field inhomogeneity. Initial human studies have shown that the radiofrequency (RF) excitation field (B1+) used for signal excitation in the heart is both inhomogeneous and significantly lower than desired, potentially leading to image artifacts and biased quantitative me...
متن کاملFeasibility of three-dimensional (3D) balanced steady-state-free-precession (bSSFP) myocardial perfusion MRI at 3 Tesla using local RF Shimming with dual-source RF transmission
Background Three-dimensional myocardial perfusion MRI offers better myocardial coverage than conventionally used two-dimensional methods. bSSFP three-dimensional myocardial perfusion MRI at 3 Tesla potentially offers further improvement of signal characteristics and may enhance the use of three-dimensional myocardial perfusion MRI for clinical application. Methods Twenty-five healthy volunteers...