Additional correction for energy transfer efficiency calculation in filter-based Forster resonance energy transfer microscopy for more accurate results.

نویسندگان

  • Yuansheng Sun
  • Ammasi Periasamy
چکیده

Forster resonance energy transfer (FRET) microscopy is commonly used to monitor protein interactions with filter-based imaging systems, which require spectral bleedthrough (or cross talk) correction to accurately measure energy transfer efficiency (E). The double-label (donor+acceptor) specimen is excited with the donor wavelength, the acceptor emission provided the uncorrected FRET signal and the donor emission (the donor channel) represents the quenched donor (qD), the basis for the E calculation. Our results indicate this is not the most accurate determination of the quenched donor signal as it fails to consider the donor spectral bleedthrough (DSBT) signals in the qD for the E calculation, which our new model addresses, leading to a more accurate E result. This refinement improves E comparisons made with lifetime and spectral FRET imaging microscopy as shown here using several genetic (FRET standard) constructs, where cerulean and venus fluorescent proteins are tethered by different amino acid linkers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Energy migration alters the fluorescence lifetime of Cerulean: implications for fluorescence lifetime imaging Forster resonance energy transfer measurements.

Forster resonance energy transfer (FRET) is a physical phenomenon used to study molecular interactions in living cells. Changes in the fluorescence lifetime of proteins genetically tagged with a donor fluorophore, such as cyan fluorescent protein or Cerulean, are used to measure energy transfer to a protein tagged with an acceptor fluorophore (yellow fluorescent protein or Venus). Increased tra...

متن کامل

Comparing the quantification of Forster resonance energy transfer measurement accuracies based on intensity, spectral, and lifetime imaging.

The measurement of Forster resonance energy transfer (FRET) in microscopes can be realized by different imaging modalities. In the present work, reference FRET constructs are developed to allow the comparison of FRET microscopy measurements using intensity, spectral, and lifetime imaging. Complimentary DNA strands are respectively labeled with Oregon Green 488 (OG488) or tetramethylrhodamine (T...

متن کامل

The Transient Dynamics of a Beam Mounted on Spring Supports and Equipped with the Nonlinear Energy Sink

The transient dynamics of a beam mounted on springer-damper support and equipped with a nonlinear energy sink (NES) is investigated under the effects of shock loads. The equations of motion are derived using the Hamilton’s principle leading to four hybrid ordinary and partial differential equations and descritized using the Galerkin method. An adaptive Newmark method is employed for accurate an...

متن کامل

Stern-Volmer modeling of steady-state Forster energy transfer between dilute, freely diffusing membrane-bound fluorophores.

Two different metrics are used to assess Forster resonance energy transfer (FRET) between fluorophores in the steady state: (i) acceptor-quenching of donor fluorescence E (also known as transfer efficiency) and (ii) donor-excited acceptor fluorescence F(A) (Dex). While E is still more widely used, F(A) (Dex) has been gaining in popularity for practical reasons among experimentalists who study b...

متن کامل

Investigating the resonance energy and charge transfer in the clonidine and c60-clonidine-fullerene carriers with quantum chemistry calculations

Clonidine has two aromatic rings in which halogens are attached to one ring in this study, both in drug state and in fullerene nanostructure, and by changing the type of halogen at the * HF / 6-31G level and in The gas phase was first optimized and then the NBO calculations were performed. The results obtained in N61, N63 and N5, N3 indicate the highest rhizanese energy and load transfer that, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 15 2  شماره 

صفحات  -

تاریخ انتشار 2010