Artifact simulating subarachnoid and intraventricular hemorrhage on single-shot, fast spin-echo fluid-attenuated inversion recovery images caused by head movement: A trap for the unwary.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Single-shot, fast spin-echo, fluid attenuated inversion recovery (SS-FSE-FLAIR) images are frequently used to detect disease in the brain and subarachnoid space in confused or uncooperative patients who may move during the examination. In some of these patients, high signal intensity areas are seen on good-quality images in the subarachnoid space and ventricular system in locations not associated with high CSF flow. These artifacts may simulate hemorrhage or leptomeningeal disease. The purpose of this article was to determine the cause of these artifacts, describe ways to recognize them, and find methods to reduce or eliminate them. METHODS Healthy volunteers were studied on 6 occasions with conventional multisection FSE-FLAIR images and SS-FSE-FLAIR images while at rest and while nodding and rotating their heads at different speeds. In addition, SS-FSE-FLAIR images with different section widths of the initial inverting pulse and a non-section-selective initial inversion pulse were performed with the subjects moving their heads in the same way. The scans of 30 successive patients with acute neurologic syndromes who had been studied with SS-FSE-FLAIR sequences were reviewed for evidence of high signal intensity in the CSF in regions not associated with high CSF flow. RESULTS Each of the volunteers showed areas of increased signal intensity in CSF at sites apart from those associated with rapid pulsatile CSF flow on SS-FSE-FLAIR images acquired during head motion. The images were otherwise virtually free of motion artifact. The use of a wider initial inversion pulse section and a non-section-selected initial inversion pulse reduced the extent of these artifacts. Nineteen of the 30 patients showed areas of high signal intensity in the CSF in regions not associated with highly pulsatile CSF flow. Six of these patients had negative lumbar punctures for blood and xanthochromia and normal CSF protein levels. CONCLUSION High signal intensity artifacts may be seen in CSF as a result of head movement on otherwise artifact-free images when imaging uncooperative patients with SS-FSE-FLAIR sequences. These artifacts have a different mechanism and distribution from those caused by CSF pulsation and may simulate subarachnoid and intraventricular hemorrhage. Artifact recognition is aided by signs of patient motion during the examination. The artifacts can be reduced by use of increased section width and non-section-selective initial inversion pulses. Recognition of these artifacts is important, because the circumstances in which the SS-FSE-FLAIR sequence is used and the particular properties of the sequence may conspire to produce a trap for the unwary.
منابع مشابه
MR imaging of hyperacute subarachnoid and intraventricular hemorrhage at 3T: a preliminary report of gradient echo T2*-weighted sequences.
We describe MR imaging findings applying gradient echo (GRE) T2*-weighted and fluid-attenuated inversion recovery (FLAIR) MR images at 3T to three patients with hyperacute subarachnoid and intraventricular hemorrhage from ruptured aneurysms. Hyperacute subarachnoid and intraventricular hemorrhages (SAH and IVH) were more clearly visualized as an area of decreased signal intensity on GRE T2*-wei...
متن کاملFast Fluid - Attenuated Inversion - Recovery MR Image in the Intracranial Tumors : Comparison with Fast Spin - echo Image
Purpose : To evaluate the significance of fluid-attenuated inversion recovery (FLAIR) magnetic resonance(MR)images for the diagnosis of intracranial tumors. Materials & Methods : MR imaging was used to study 15 patients with various intracranial tumors and were compared the findings according to fast spin echo and fast FLAIR images . Resu Its : In 12 of 15 patients, tumor signal intensities on ...
متن کاملComparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملApplicability and advantages of flow artifact-insensitive fluid-attenuated inversion-recovery MR sequences for imaging the posterior fossa.
We describe a new sequence, flow artifact-insensitive fluid-attenuated inversion recovery (FAIS-FLAIR), that capitalizes on the advantages of fluid-attenuated inversion recovery (FLAIR) while minimizing FLAIR-related artifacts such as those often encountered in the posterior fossa. Twenty-eight patients with posterior fossa disease underwent FAIS-FLAIR, conventional FLAIR, and spin-echo MR stud...
متن کاملDetection of subarachnoid haemorrhage with magnetic resonance imaging.
OBJECTIVES To measure the sensitivity and specificity of five MRI sequences to subarachnoid haemorrhage. METHODS Forty one patients presenting with histories suspicious of subarachnoid haemorrhage (SAH) were investigated with MRI using T1 weighted, T2 weighted, single shot fast spin echo (express), fluid attenuation inversion recovery (FLAIR), and gradient echo T2* sequences, and also by CT. ...