Development of PVE Refrigeration Lubricants for R32

نویسندگان

  • Tomoya Matsumoto
  • Yasuhiro Kawaguchi
  • Tomoya MATSUMOTO
  • Masato KANEKO
  • Yasuhiro KAWAGUCHI
چکیده

A New-PVE lubricant was developed for use with R32 refrigerant. R32 has been proposed as an alternative refrigerant for R410A refrigerant, to reduce global warming. In this report, we evaluated the relationship between the New-PVE lubricant and R32 and R410A refrigerants. The evaluation items were physical properties (miscibility, solubility, mixture viscosity and volumetric resistivity) and thermal stability and lubricity. In addition, a New-PVE was also developed to improve miscibility with R32 refrigerant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Energetic and Exergetic Analysis of an Ejector-Expansion Refrigeration Cycle Using the Working Fluid R32

The performance characteristics of an ejector-expansion refrigeration cycle (EEC) using R32 have been investigated in comparison with that using R134a. The coefficient of performance (COP), the exergy destruction, the exergy efficiency and the suction nozzle pressure drop (SNPD) are discussed. The results show that the application of an ejector instead of a throttle valve in R32 cycle decreases...

متن کامل

Thermodynamic Analysis of Refrigerators Using Different Refrigerants

Refrigerants that are used in refrigeration systems, cause environmental difficulties such as depletion of ozone layer and greenhouse effect. Thus, we must find substitutes for such refrigerants, in this paper, the effect of refrigerant on the thermodynamics performance of refrigeration cycles are studied. To do this, a refrigerator that has designed for R12, is simulated. Results show that pur...

متن کامل

Thermodynamic Analysis of Refrigerators Using Different Refrigerants

Refrigerants that are used in refrigeration systems, cause environmental difficulties such as depletion of ozone layer and greenhouse effect. Thus, we must find substitutes for such refrigerants, in this paper, the effect of refrigerant on the thermodynamics performance of refrigeration cycles are studied. To do this, a refrigerator that has designed for R12, is simulated. Results show that pur...

متن کامل

Development of Polyol Ester Refrigeration Oils for HFO Refrigerants

Recently, R32 refrigerant, which has low global warming potential (GWP), attracts much attention as an alternative one instead of R410A and has started to be used in practical systems of room air conditioners (RAC), but compared with natural refrigerants, its GWP of 675 is still high and it is required to use refrigerants with much lower GWP. In addition, although R134a (GWP=1300) is widely use...

متن کامل

A New Synthetic Hybrid Refrigeration Oil for R410A and R407C

There is a need to improve conventional polyolester lubricants that are currently being evaluated as the optimal refrigeration base oil for the alternative refrigerants R41 OA and R407C, which are expected to be designated as the replacement ofHCFC 22. Prior studies show that the conventional polyolesters and other lubricants have poor hydrolysis and solubility. This paper is an introduction to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014