Simultaneous acquisition of gradient-echo and asymmetric spin-echo for single-shot z-shim: Z-SAGA.
نویسندگان
چکیده
This article describes the Z-SAGA pulse sequence, a technique for recovering susceptibility losses in EPI images for neuroimaging applications. The pulse sequence is based on an asymmetric spin echo EPI sequence and acquires a gradient echo image and an asymmetric spin echo image in a single shot. For one of the images, a z-shim gradient pulse is applied to compensate for susceptibility-related field distortions. The two images are combined to form an image with reduced signal loss. This sequence is simple to implement and experimentally demonstrated to be effective for BOLD imaging.
منابع مشابه
Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملMultiple gradient- and spin-echo EPI acquisition technique with z-shimming to compensate for susceptibility-induced off- resonance effects
INTRODUCTION – Images obtained with gradient-echo echo planar imaging (GRE-EPI) suffer from magnetic field variations within the brain, such as in regions adjacent to air-tissue interfaces. In these regions, magnetic field inhomogeneities cause spins to dephase more rapidly, resulting in signal dropouts. Thus, conventional GRE-EPI pulse sequences used for dynamic susceptibility-contrast perfusi...
متن کاملVolumetric R2 * mapping using z-shim multi-echo gradient echo imaging.
PURPOSE To introduce macroscopic B0 field inhomogeneity-compensated volumetric R2 * mapping method with a three-dimensional (3D) z-shim multi-echo acquisition. METHODS The proposed z-shim sequence acquired conventional and z-shimmed echoes alternately with bipolar readout gradients. A constant-valued z-shim gradient was applied prior to each negative readout gradient lobe. A phase combination...
متن کاملاندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی
Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...
متن کاملImproved liver T1rho measurement precision with a breathhold black blood single shot fast spin echo acquisition: a validation study in healthy volunteers
Purpose: To explore the usability and normal T1rho value of liver parenchyma with a novel single breathhold black blood single shot fast spin echo acquisition based liver imaging sequence. Materials and Methods: The institutional Ethics Committee approved this study. In total 19 health subjects (10 males, 9 females; mean age: 37.4 yrs; range: 23-54 yrs) participated in the study. 11 subjects ha...