Laser lead extraction to facilitate cardiac implantable electronic device upgrade and revision in the presence of central venous obstruction

نویسندگان

  • Manav Sohal
  • Steven Williams
  • Majid Akhtar
  • Amit Shah
  • Zhong Chen
  • Matthew Wright
  • Mark O'Neill
  • Nik Patel
  • Shoaib Hamid
  • Michael Cooklin
  • Cliff Bucknall
  • Julian Bostock
  • Jaswinder Gill
  • Christopher Aldo Rinaldi
چکیده

AIMS The number of procedures involving upgrade or revision of cardiac implantable electronic devices (CIEDs) is increasing and the risks of adding additional leads are significant. Central venous occlusion in patients with pre-existing devices is often asymptomatic and optimal management of such patients in need of device revision/upgrade is not clear. We sought to assess our use of laser lead extraction in overcoming venous obstruction. METHODS AND RESULTS Patients in need of device upgrade/revision underwent pre-procedure venography to assess venous patency. In patients with venous occlusion or stenosis severe enough to preclude passage of a hydrophilic guide wire, laser lead extraction with retention of the outer sheath in the vasculature was performed with the aim of maintaining a patent channel through which new leads could be implanted. Data were recorded on a dedicated database and patient outcomes were assessed. Between July 2004 and April 2012, laser lead extractions were performed in 71 patients scheduled for device upgrade/revision who had occluded or functionally obstructed venous anatomy. New leads were successfully implanted across the obstruction in 67 (94%) cases. There were two major complications (infection) and four minor complications with no peri-procedural mortality. Device follow-up was satisfactory in 65 (92%) cases with mean follow-up up to 26 ± 19 months. CONCLUSION Laser lead extraction is a safe and effective option when managing patients with central venous obstruction in need of CIED revision or upgrade.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Overcoming a subclavian complete occlusion: Simple single lead extraction by the subclavian vein allowing implantation of two new leads and upgrade to CRT-P with multi-site pacing.

Central venous obstruction following pacemaker implantation is not uncommon, and can prove challenging in the case of system upgrade. We report a case of DDDR to CRT-P (with multi-site pacing) upgrade, where a subclavian occlusion was overcome resorting to an atrial lead extraction (using only a locking stylet). This allowed regaining of the venous access with subsequent implantation of not jus...

متن کامل

Incidence of venous obstruction following insertion of an implantable cardioverter defibrillator. A study of systematic contrast venography on patients presenting for their first elective ICD generator replacement.

AIMS The number of implantable cardioverter defibrillator (ICD) implantations, as well as follow-up procedures such as generator exchanges, lead revisions and lead system upgrades, is ever-increasing. Lead revisions and implantation of additional leads require venous access at the site of the previous ICD implantation. The aim of our study was therefore to evaluate the incidence of venous obstr...

متن کامل

Partial extravenous course of cardiac pacemaker leads. A major risk during device-assisted extraction

Introduction The intracardiac electronic device implantation rate has been constantly increasing for the last 20 years and is accompanied by an increasing lead extraction rate. Percutaneous extraction of transvenous leads of cardiovascular implantable electronic devices is mandatory in the case of pocket infection and/or system infection, resulting in valvular or lead endocarditis. Lead extract...

متن کامل

Effectiveness of Permanent Implantable Catheter (Polysite) in Children with Cancer

Abstract Background Totally implantable central venous access devices (ports) have been available for over 10 years, but have not been achieved widespread use in pediatric oncology patients. Ports facilitate the administration of chemotherapy in children with cancer. Materials and Methods In this study, early complications of implantable central venous access devices in children with diff...

متن کامل

Laser assisted extraction of pacemaker and implantable defibrillator leads.

OBJECTIVE To analyze the results of laser-assisted extraction of permanent pacemaker and defibrillator leads. METHODS We operated upon 36 patients, whose mean age was 54.2 years, and extracted 56 leads. The reasons for extracting the leads were as follows: infection in 19 patients, elective replacement in 13, and other causes in 4 patients. The mean time of catheter placement was 7.5+/-5.5 ye...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014