Direct Sampling Method for Diffusive Optical Tomography

نویسندگان

  • Yat Tin Chow
  • Kazufumi Ito
  • Keji Liu
  • Jun Zou
چکیده

In this work, we are concerned with the di↵usive optical tomography (DOT) problem in the case when only one or two pairs of Cauchy data is available. We propose a simple and e cient direct sampling method (DSM) to locate inhomogeneities inside a homogeneous background and solve the DOT problem in both full and limited aperture cases. This new method is easy to implement and less expensive computationally. Numerical experiments demonstrate its e↵ectiveness and robustness against noise in the data. This provides a new promising numerical strategy for the DOT problem. Mathematics Subject Classification (MSC2000): 35J67, 35R30, 65N21, 78A70, 78M25.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved importance sampling for Monte Carlo simulation of time-domain optical coherence tomography

We developed an importance sampling based method that significantly speeds up the calculation of the diffusive reflectance due to ballistic and to quasi-ballistic components of photons scattered in turbid media: Class I diffusive reflectance. These components of scattered photons make up the signal in optical coherence tomography (OCT) imaging. We show that the use of this method reduces the co...

متن کامل

Fast calculation of multipath diffusive reflectance in optical coherence tomography

We show how to efficiently calculate the signal in optical coherence tomography (OCT) systems due to the ballistic photons, the quasi-ballistic photons, and the photons that undergo multiple diffusive scattering using Monte Carlo simulations with importance sampling. This method enables the calculation of these three components of the OCT signal with less than one hundredth of the computational...

متن کامل

Feasibility of Direct Digital Sampling for Diffuse Optical Frequency Domain Spectroscopy in Tissue.

Frequency domain optical spectroscopy in the diffusive regime is currently being investigated for biomedical applications including tumor detection, therapy monitoring, exercise metabolism, and others. Analog homodyne or heterodyne detection of sinusoidally modulated signals have been the predominant method for measuring phase and amplitude of photon density waves that have traversed through ti...

متن کامل

Monte Carlo simulation of optical coherence tomography for turbid media with arbitrary spatial distributions.

We developed a Monte Carlo-based simulator of optical coherence tomography (OCT) imaging for turbid media with arbitrary spatial distributions. This simulator allows computation of both Class I diffusive reflectance due to ballistic and quasiballistic scattered photons and Class II diffusive reflectance due to multiple scattered photons. It was implemented using a tetrahedron-based mesh and imp...

متن کامل

Siemens primus accelerator simulation using EGSnrc Monte Carlo code and gel dosimetry validation with optical computed tomography system by EGSnrc code

Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. Monte Carlo modeling of the Siemens Primus linear accelerator in 6 MeV beams was used. Square field size of 10 × 10 cm2 produced by the jaws was compared with TLD. Head simulation of Siemens accele...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • SIAM J. Scientific Computing

دوره 37  شماره 

صفحات  -

تاریخ انتشار 2015