Beam Position Monitor Offset Determination at Lep
نویسندگان
چکیده
For the performance of an electron positron storage ring it is important that the beam orbit passes well centred through the quadrupole magnets. Beam position monitors (BPM) aligned relative to the magnets can still have a residual mechanical or electronical offset with respect to the magnetic axis. A beam-based method is used at LEP to measure these offsets. During the machine operation for physics the gradient of selected quadrupoles is modulated with low frequencies (few Hz) and very small amplitudes (of the order of 10 ). The effect on the beam is observed with a high sensitivity pick-up. The observed effect passes through a minimum when the beam is centred in the quadrupole. Offsets for about 70 different BPM’s were determined. Systematically different offsets were found for different type of BPM electronics and different types of quadrupoles. Simulations based on the past results show that the level of spin polarisation can be increased by further offset measurements.
منابع مشابه
Ground Motion in Lep and Lhc
It is well known that large colliders, linear or circular, with small beam sizes are prone to ground motion effects.The effect of seismic perturbations on machine performance has been the subject of several studies[1,2,3,4]. The object of this paper is to report on the results obtained with a dedicated beam position monitor, concerning ground motion effects on the LEP beams. Since the ultimate ...
متن کاملMeasurements and Visualization of the Transverse Phase-space Topology at Lep
The LEP Beam Orbit Measurement system (BOM) allows for the acquisition of the beam position at each Beam Position Monitor (BPM) for over 1000 consecutive turns. By synchronizing the acquisition with a kick given to the beam, we can investigate the behavior of the beam under different conditions. In particular, starting from the data of one BPM, we can apply a simple mathematical manipulation to...
متن کاملWake-field in an array of metallic posts: Possible application for beam position monitoring
It is proposed to use an array of metallic posts as a beam position monitor (BPM). The structure consists of a set of N N metallic vertical posts bounded from above and below by two horizontal metallic plates. The beam position offset from the symmetry axis is determined by measuring the backward radiation emitted by the beam as it traverses the array. The suggested BPM’s position resolution is...
متن کاملMeasurements of Tune Shifts with Amplitude at Lep
The beam orbit system of the LEP electron-positron collider is able to store the beam position over 1000 turns following a deflection by a horizontal kicker. A precise analysis of such 1000-turn data for many beam position monitors was used to study the dependence of the tune on the horizontal amplitude. The horizontal tune shift with amplitude was determined from the decay of the beam oscillat...
متن کاملCalibration of centre - of - mass energies at LEP 2 for a precise measurement of the W boson mass The LEP Energy Working Group
The determination of the centre-of-mass energies for all LEP 2 running is presented. Accurate knowledge of these energies is of primary importance to set the absolute energy scale for the measurement of the W boson mass. The beam energy between 80 and 104 GeV is derived from continuous measurements of the magnetic bending field by 16 NMR probes situated in a number of the LEP dipoles. The relat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -