Retinal function of the diabetic retina after argon laser photocoagulation assessed electroretinographically.

نویسندگان

  • I Perlman
  • M Gdal-On
  • B Miller
  • S Zonis
چکیده

Electroretinographic (ERG) responses were measured in diabetic patients before, during, and after panretinal photocoagulation treatment with argon laser. The laser applications reduced considerably the amplitudes of the a and b waves of the ERG. Moreover, the relationship between the amplitude of the b wave and that of the a wave was severely affected, resulting in ERG responses of abnormal pattern. The b waves were smaller than expected from the a waves. These findings indicated that the photocoagulation treatment not only destroyed the retinal areas directly illuminated by the laser beam, but also affected the functional integrity of adjacent areas. These additional effects resulted in subnormal signal transmission from the photoreceptors to the proximal retina.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recovery of the electroretinogram in rabbits after argon laser photocoagulation.

Argon laser is widely used to coagulate the diabetic retina in order to inhibit the proliferative stage of diabetic retinopathy. Ten pigmented rabbits underwent retinal photocoagulation with argon laser. Retinal function was assessed electroretinographically before treatment and at different time intervals after treatment. The ERG responses measured 4-7 days after treatment were reduced in ampl...

متن کامل

Effects of Laser Physical Parameters on Lesion Size in Retinal Photocoagulation Surgery: Clinical OCT and Experimental Study

Introduction: The aim of the present study was to determine burn intensity in retinal laser photocoagulation based on laser parameters; wavelength, power, beam size and pulse duration, using Optical Coherence Tomography (OCT), fundus camera, physical eye model and computer simulation in a clinical study.Materials and Methods: Participants were 10 adult patients between 50-80 years with prolifer...

متن کامل

Binocular indirect argon laser photocoagulator.

The binocular indirect argon laser photocoagulator was newly designed to enable visualisation of the entire fundus during panretinal laser photocoagulation and to treat retinal tears immediately after buckling procedures of the sclera. The lamp housing of the binocular ophthalmoscope was remodelled and adjusted so that the laser beam and illuminating light are coaxial after leaving the ophthalm...

متن کامل

Subthreshold micropulse diode laser treatment in diabetic macular oedema.

BACKGROUND/AIM Enlargement of laser scars after retinal argon laser photocoagulation can give rise to deterioration in visual acuity. Subthreshold micropulse diode laser may decrease this risk. The aim of this study was to compare the effectiveness of subthreshold micropulse diode laser (810 nm) and conventional argon laser (514 nm) photocoagulation for the treatment of clinically significant m...

متن کامل

A comparative trial of xenon arc and argon laser photocoagulation in the treatment of proliferative diabetic retinopathy.

We present the results of a randomised study comparing xenon arc and argon laser photocoagulation in the treatment of proliferative diabetic retinopathy. Our results show that when used in the way described below there is no significant difference between the effect of the 2 treatments on optic disc neovascularisation and visual acuity. We also compare the results of peripheral retinal ablation...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 69 4  شماره 

صفحات  -

تاریخ انتشار 1985