Simultaneous dual-energy X-ray stereo imaging
نویسندگان
چکیده
Dual-energy or K-edge imaging is used to enhance contrast between two or more materials in an object and is routinely realised by acquiring two separate X-ray images each at different X-ray wavelength. On a broadband synchrotron source an imaging system to acquire the two images simultaneously was realised. The single-shot approach allows dual-energy and stereo imaging to be applied to dynamic systems. Using a Laue-Bragg crystal splitting scheme, the X-ray beam was split into two and the two beam branches could be easily tuned to either the same or to two different wavelengths. Due to the crystals' mutual position, the two beam branches intercept each other under a non-zero angle and create a stereoscopic setup.
منابع مشابه
Compensation of Cross-Contamination in Simultaneous 201Tl/99mTc Myocardial Perfusion SPECT Imaging
Introduction: It is a common protocol to use 201Tl for the rest and 99mTc for the stress cardiac SPECT imaging. Theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. However, a potential limitation is the cross-contamination of scattered photons from 99mTc and collimator X-rays into the 201Tl energy window. We used a middle en...
متن کاملارزیابی میزان دقت جداسازی تصاویر دو ماده حاجب مختلف به صورت همزمان از بافت پستان با استفاده از تکنیک ماموگرافی دیجیتال دو انرژی
Background and purpose: Dual-energy mammography is a technique which is used to enhance the accuracy of breast cancer diagnosis especially in dense breasts. This study was conducted based on the simultaneous use of two contrast agents for automatic separation and also to evaluate their accuracy using dual-energy digital mammography. Materials and methods: A breast phantom was designed and b...
متن کاملComparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus
The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...
متن کاملبررسی امکان تشخیص اتوماتیک میکروکلسیم های بافت پستان با استفاده از تکنیک دو انرژی تصویربرداری اشعه ایکس جهت تشخیص زودرس سرطان پستان
Background and purpose: Dual-energy mammography technique is used for improving the accuracy of breast cancer diagnosis especially in dense breast cases and also detection of micro-calcifications which are early signs of breast cancer. The purpose of this study was to investigate the automatic separation feasibility of micro-calcification images in breast tissue images and evaluating its accura...
متن کاملDual-energy CT in the Chest
Dual-energy CT (DECT) is accomplished by near simultaneous imaging at two energy levels, typically 80 kV and 140 kV, using scanners that either employ rapid kV switching or have two orthogonal sets of X-ray tunes and detectors mounted in the gantry. Attenuation properties differ at the two energy levels, which allow the DECT to differentiate and quantify certain substances such as water, calciu...