Toward an MRI-based method to measure non-uniform cartilage deformation: an MRI-cyclic loading apparatus system and steady-state cyclic displacement of articular cartilage under compressive loading.

نویسندگان

  • C P Neu
  • M L Hull
چکیده

Recent magnetic resonance imaging (MRI) techniques have shown potential for measuring non-uniform deformations throughout the volume (i.e. three-dimensional (3D) deformations) in small orthopedic tissues such as articular cartilage. However, to analyze cartilage deformation using MRI techniques, a system is required which can construct images from multiple acquisitions of MRI signals from the cartilage in both the underformed and deformed states. The objectives of the work reported in this article were to 1) design an apparatus that could apply highly repeatable cyclic compressive loads of 400 N and operate in the bore of an MRI scanner, 2) demonstrate that the apparatus and MRI scanner can be successfully integrated to observe 3D deformations in a phantom material, 3) use the apparatus to determine the load cycle necessary to achieve a steady-state deformation response in normal bovine articular cartilage samples using a flat-surfaced and nonporous indentor in unconfined compression. Composed of electronic and pneumatic components, the apparatus regulated pressure to a double-acting pneumatic cylinder so that (1) load-controlled compression cycles were applied to cartilage samples immersed in a saline bath, (2) loading and recovery periods within a cycle varied in time duration, and (3) load magnitude varied so that the stress applied to cartilage samples was within typical physiological ranges. In addition the apparatus allowed gating for MR image acquisition, and operation within the bore of an MRI scanner without creating image artifacts. The apparatus demonstrated high repeatability in load application with a standard deviation of 1.8% of the mean 400 N load applied. When the apparatus was integrated with an MRI scanner programmed with appropriate pulse sequences, images of a phantom material in both the underformed and deformed states were constructed by assembling data acquired through multiple signal acquisitions. Additionally, the number of cycles to reach a steady-state response in normal bovine articular cartilage was 49 for a total cycle duration of 5 seconds, but decreased to 33 and 27 for increasing total cycle durations of 10 and 15 seconds, respectively. Once the steady-state response was achieved, 95% of all displacements were within +/- 7.42 microns of the mean displacement, indicating that the displacement response to the cyclic loads was highly repeatable. With this performance, the MRI-loading apparatus system meets the requirements to create images of articular cartilage from which 3D deformation can be determined.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quasi-steady-state displacement response of whole human cadaveric knees in a MRI scanner.

It is important to determine the three-dimensional nonuniform deformation of articular cartilage in its native environment. A new magnetic resonance imaging (MRI)-based technique (cartilage deformation by tag registration (CDTR)) has been developed, which can determine such deformations provided that the compressive load-displacement response of the knee reaches a quasi-steady state during cycl...

متن کامل

Tibiofemoral Cartilage Deformation Determined in Cyclic Compression by Displacement-Encoded MRI

Introduction: Measurement of articular cartilage deformation is important to characterize the differences between healthy and pathological tissue and to compare native tissue with engineered constructs. Among these differences is the nonuniform distribution of extracellular matrix proteins through the tissue depth, which in turn gives rise to heterogeneous strains and anisotropic mechanical pro...

متن کامل

In situ deformation of cartilage in cyclically loaded tibiofemoral joints by displacement-encoded MRI.

OBJECTIVES Cartilage displacement and strain patterns were documented noninvasively in intact tibiofemoral joints in situ by magnetic resonance imaging (MRI). This study determined the number of compressive loading cycles required to precondition intact joints prior to imaging, the spatial distribution of displacements and strains in cartilage using displacement-encoded MRI, and the depth-depen...

متن کامل

Cartilage Nominal Strain Correlates with Gag Content and Shear Modulus in Meniscectomized Joints

* **Song, Y, **Greve, J, **Gold, GE, * **Carter, DR, * **Giori, NJ * Bone and Joint Center, VA Palo Alto Health Care System, Palo Alto, CA [email protected] INTRODUCTION Meniscectomy leads to osteoarthritis (OA) in both human and animal knee joints. Spatial changes in biochemical composition and biomechanical properties over the entire surface of articular cartilage following meniscectomy h...

متن کامل

Heterogeneous three-dimensional strain fields during unconfined cyclic compression in bovine articular cartilage explants.

Articular cartilage provides critical load-bearing and tribological properties to the normal function of diarthrodial joints. The unique properties of cartilage, as well as heterogeneous deformations during mechanical compression, are due to the nonuniform microstructural organization of tissue components such as collagens and proteoglycans. A new cartilage deformation by tag registration (CDTR...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomechanical engineering

دوره 125 2  شماره 

صفحات  -

تاریخ انتشار 2003