Differences in Recognition of the First WHO International Reference Reagents for hCG-Related Isoforms by Diagnostic Immunoassays for Human Chorionic Gonadotropin

نویسندگان

  • Catharine Sturgeon
  • Peter Berger
  • Jean-Michel Bidart
  • Steven Birken
  • Chris Burns
  • Rob Norman
  • Ulf-Håkan Stenman
چکیده

RESULTS: Differences in calibration of current hCG assays are moderate. Mean recovery of the current International Standard (IS), hCG IS 75/589, was 107% (range 93% to 126%), whereas that of the IRR 99/688 for hCG was 139% (range 109%–164%). Betweenmethod variation for the latter (CV 12.3%) was also greater than for IS 75/589 (CV 8.8%). Recognition of hCG varied markedly (CV 37%). Most assays led to overestimation, but 2 RIAs produced results that were slight underestimations. Recognition of the hCG core fragment was even more variable (CV 57%) and was closest to equimolarity for the RIAs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differences in recognition of the 1st WHO international reference reagents for hCG-related isoforms by diagnostic immunoassays for human chorionic gonadotropin.

BACKGROUND The 1st WHO International Reference Reagents (IRRs) for 6 human chorionic gonadotropin (hCG)-related molecular variants, highly purified and calibrated in substance concentrations by the IFCC Working Group for hCG, permit experimental elucidation of what commercially available hCG methods measure in molar terms and enable assessment of their fitness for clinical purposes. METHODS P...

متن کامل

Human chorionic gonadotropin isoforms and their epitopes: diagnostic utility in pregnancy and cancer.

BACKGROUND Clinical management of pregnancy, pregnancy-related disorders and trophoblastic tumors is dependent on immunoassay measurements of the complex analyte human chorionic gonadotropin (hCG). Differences in hCG results using different methods affect clinical interpretation with potentially adverse consequences for patient care. Objectives/method: To provide an overview of factors contribu...

متن کامل

Establishment, value assignment, and characterization of new WHO reference reagents for six molecular forms of human chorionic gonadotropin.

BACKGROUND The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) established a Working Group to investigate means of improving the comparability of immunoassays for human chorionic gonadotropin (hCG), which was selected as a prototype glycoprotein analyte. The Working Group identified development of unambiguous nomenclature and production of new highly purified Inter...

متن کامل

Quantification of Human Chorionic Gonadotropin by Bovine Serum Albumin Nanoparticles

Background and Aims: Some nanoparticles can be used in immunoassays to increase sensitivity. This study aimed to evaluate a novel nano-immunoassay based on bovine serum albumin nanoparticles (BSA NPs). Materials and methods: At first, the nanostructure was synthesized, and then applied as a tag in the nano-immunoassay. Then the concentration of β-subunit of human chorionic gonadotropin ...

متن کامل

P-234: Expression of Human Chorionic Gonadotropin (hCG) Hormone Using Chinese Hamster Ovary Cells

Background: Human chorionic gonadotropin (hCG) is a member of glycoprotein hormones family consist of two different non-covalently heterodimeric chains: alpha and beta subunits with 92 and 145 amino acids respectively. This hormone plays an important role in human reproduction and physiology especially for maintenance of the corpus luteum during the first months of pregnancy Materials and Metho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009