Accuracy of clinical protocols in SPECT.

نویسندگان

  • Asena Kurt
  • Doğan Bor
  • Selma Tastan
  • Semra Donmez
  • Tuba Haciosmanoğlu
چکیده

UNLABELLED The accuracy of clinical SPECT is highly dependent on the acquisition and processing parameters, which are selected according to the clinical task. These parameters are usually set within protocols in order to allow for standardization from one study to another and to speed up the clinical routine. METHODS In the first part of this work, tomographic images of a Jaszczak phantom were obtained on 5 different SPECT systems using 2 common clinical protocols and each system's default acquisition and processing parameters. In the second part, tomographic images of the Jaszczak phantom were obtained using identical acquisition and processing parameters on all systems. Projection data were then transferred to other system software for reconstruction. RESULTS For the first part of the work, variation in image quality was seen quantitatively among the systems, even when clinical protocols with the same aim were used. The accuracy of the similar reconstruction algorithms and data transfer was determined and summarized. In the second part of this study, the performance of the SPECT systems using similar acquisition protocols and reconstruction software was determined and summarized. CONCLUSION The default clinical protocols offered by the manufacturer for similar studies may be different from one another. The user should modify these protocols using phantom studies and standardize same-purpose protocols among different software programs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Current state of bone scintigraphy protocols and practice in Japan

Objective(s): Nuclear medicine technologists in Japan often perform additional single-photon emission computed tomography (SPECT) with or without computed tomography (CT) after whole-body imaging for bone scintigraphy. In this study, we wanted to identify the bone scanning protocols used in Japan, together with the current clinical practices. Methods:...

متن کامل

Accuracy of SPECT bone scintigraphy in diagnosis of meniscal tears

Introduction: Scintigraphy has been considered as a useful tool in the assessment of meniscal tears. Our objective was to assess the accuracy of single photon emission tomography (SPECT), using MRI as the gold standard, in the diagnosis of meniscal tears. Materials and Methods: Between January 2003 and February 2005, 45 patients were studied with SPECT and MRI. Results: The respective sen...

متن کامل

Review of transmission scanning configurations in cardiac SPECT

The diagnostic accuracy of single photon emission computed tomography (SPECT) is profoundly influenced by attenuation phenomenon. Soft tissue attenuation degrades cardiac SPECT image quality, thereby decreasing the possibility of the detection of the lesions. A variety of correction techniques based on different assumptions have been used to reduce the impact of attenuation. Several types of sy...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

The influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies

Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 40 4  شماره 

صفحات  -

تاریخ انتشار 2012