Correlation of SPECT imaging, biochemical parameters and mutation with systolic dysfunction.

نویسندگان

  • D Alenizi
  • N A Kizilbash
  • O Gill
  • A Abukanna
  • S Malik
  • A Badawy
چکیده

We investigated systolic dysfunction by the use of biochemical laboratory tests and perfusion single-photon emission computed tomography imaging in 32 Pakistani subjects exhibiting symptoms of this disorder. To investigate underlying genetic causes, such as familial hypercholesterolemia, DNA samples from these subjects were screened by PCR-SSCP and DNA sequencing to detect changes in the low density lipoprotein receptor gene (LDLR). A novel mutation (1171G>A) in exon 8 and two polymorphisms (1167G>A and 1413 A>G) in exons 8 and 10 of the LDLR gene were found. In silico tools such as SIFT, PolyPhen-2, KD4v, and Project HOPE were used to predict the effect of this mutation on protein structure and function.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Brain Single Photon Emission Computed Tomography Scan (SPECT) and Functional MRI in Systemic Lupus Erythematosus Patients with Cognitive Dysfunction: A Systematic Review

Objective(s): Systemic lupus erythematosus (SLE) is an autoimmune disease with a wide range of clinical manifestations. Cognitive dysfunction is one of the manifestations that could present prior to the emergence of any other neuropsychiatric involvements in SLE. Cognitive dysfunction is a subtle condition occurring with ahigh frequency. However, there is no data on the correlation of cognitive...

متن کامل

The role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method

Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...

متن کامل

Diastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography

Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

Impact of reconstruction method on quantitative parameters of 99mTc-TRODAT-1 SPECT

Introduction: Quantitative evaluation is recommended to improve diagnostic ability and serial assessment of dopamine transporter (DAT) density scans. We decided to compare the ordered subsets expectation-maximization (OSEM) with filtered back-projection (FBP), and to investigate the impact of different iteration and cut-off frequencies on SBR values. Methods</stro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Genetics and molecular research : GMR

دوره 12 4  شماره 

صفحات  -

تاریخ انتشار 2013