Measuring recovery from general anaesthesia using critical flicker frequency: a comparison of two methods.
نویسندگان
چکیده
Critical flicker frequency (CFF) is the frequency at which a flickering light appears steady. It is a sensitive measure for assessing recovery from anaesthesia. The CFF is almost always determined with the method of limits by which the flickering frequency is progressively decreased (or increased) until the patient reports a change from fusion to flicker (or flicker to fusion). This method has two disadvantages: it is influenced by the response bias (i.e., the subjective criterion used by the subject to decide that flicker is present or absent) and by the response delay (i.e., the interval between the perceptual change and the response). To avoid these problems, the method of forced choice is recommended. For each trial, the subject observes the light during two short successive periods. The light flickers during only one period, according to chance. The patient must indicate the period during which flickers occur. If uncertain, the patient has to make a guess. The aim of this study was to compare the two methods for assessing recovery from general anaesthesia. Two induction agents were used to obtain different recovery profiles. Twenty patients undergoing uncomplicated surgery lasting less than two hours were tested. They received either thiopentone or midazolam for induction, according to a randomized design. Vecuronium was used to facilitate tracheal intubation and anaesthesia was maintained with fentanyl, isoflurane and nitrous oxide. The CFF was measured before induction and at 60, 120 and 180 minutes after arrival in the recovery room. The person measuring CFF was unaware of the induction agent used.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Immediate Effects of Different Screen Sizes on Visual Fatigue in Video Display Terminal Users
Background: Computer usage has rapidly grown. This is because it helps to resolve problems, i.e., encountered in daily life by individuals. Various monitor screens that have been developed affect the userchr('39')s eyes. Screen size is one of the relevant impacts. Thus, this study compared the immediate effects of two computer screen sizes on visual fatigue in Video Display Terminal (VDT) users...
متن کاملVoltage Flicker Parameters Estimation Using Shuffled Frog Leaping Algorithm and Imperialistic Competitive Algorithm
Measurement of magnitude and frequency of the voltage flicker is very important for monitoring andcontrolling voltage flicker efficiently to improve the network power quality. This paper presents twonew methods for measurement of flicker signal parameters using Shuffled Frog Leaping Algorithm(SFLA) and Imperialist Competitive Algorithm (ICA). This paper estimates fundamental voltage andflicker ...
متن کاملUse of simple tests to determine the residual effects of the analgesic component of balanced anaesthesia.
In order to evaluate simple means of determining the rate of recovery after general anaesthesia, the usefulness of the critical flicker fusion threshold test, the Maddox wing apparatus and the visual analogue scale were compared. The postanaesthetic recovery score was used as a reference. Two patient groups (n = 15 in each) received, in a randomized double-blind study, a similar balanced anaest...
متن کاملبررسی عوامل بیهوشی عمومی با ماسک در بیماران تحت عمل جراحی در یکی از بیمارستانهای وابسته به دانشگاه علوم پزشکی ایران(1372)
This research project is a field study to investigate the complications of general anaesthesia with mask in patients under surgery in a hospital affiliated to University of Medical Sciences Iran. The specific goals of this study are as follows: -To determine some of the characters of patients under study. -To determine the complications of general anesthesia with mask during surgery in on...
متن کاملMeasuring of Residual Stress in TIG Welding of the 304 Stainless Steel by Ultrasonic Method
In this research, the effect of different welding parameters on residual stress and microstructure of the weld region, as well as the comparison of two methods of measuring residual stress using critical fracture longitudinal wave method and preformation method have been investigated. For this purpose, the taguchi DOE methodology is used as a statistical method to optimize four parameters of pu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Canadian journal of anaesthesia = Journal canadien d'anesthesie
دوره 39 10 شماره
صفحات -
تاریخ انتشار 1992