Pullout capacity of batter pile in sand

نویسندگان

  • Ashraf Nazir
  • Ahmed Nasr
چکیده

Many offshore structures are subjected to overturning moments due to wind load, wave pressure, and ship impacts. Also most of retaining walls are subjected to horizontal forces and bending moments, these forces are due to earth pressure. For foundations in such structures, usually a combination of vertical and batter piles is used. Little information is available in the literature about estimating the capacity of piles under uplift. In cases where these supporting piles are not vertical, the behavior under axial pullout is not well established. In order to delineate the significant variables affecting the ultimate uplift shaft resistance of batter pile in dry sand, a testing program comprising 62 pullout tests was conducted. The tests are conducted on model steel pile installed in loose, medium, and dense sand to an embedded depth ratio, L/d, vary from 7.5 to 30 and with various batter angles of 0°, 10°, 20°, and 30°. Results indicate that the pullout capacity of a batter pile constructed in dense and/or medium density sand increases with the increase of batter angle attains maximum value and then decreases, the maximum value of Pα occurs at batter angle approximately equal to 20°, and it is about 21-31% more than the vertical pile capacity, while the pullout capacity for batter pile that constructed in loose sand decreases with the increase of pile inclination. The results also indicated that the circular pile is more resistant to pullout forces than the square and rectangular pile shape. The rough model piles tested is experienced 18-75% increase in capacity compared with the smooth model piles. The suggested relations for the pullout capacity of batter pile regarding the vertical pile capacity are well predicted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pullout Capacity of Model Piles in Sand

A large scale experimental program using vertical and batter model piles in sand subjected to pull out loads has been carried out in a model tank of size 1m x 1m x 1m. Mild steel pipes of varying diameters, lengths, and shapes are used as model piles. A poorly graded river sand having specific gravity G= 2.67, Uniformity coefficient= 3.53, emax = 0.81, emin = 0.54 has been used as foundation me...

متن کامل

بهسازی لرزه‌ای اسکله‌های شمع و عرشه به وسیله جداگرهای لرزه‌ای

There are significant number of pile supported wharves around the world and this type of structures are commonly chosen for the construction of new waterfront port facilities. Batter piles have been used for a long time to resist large lateral loads from winds, water waves, impacts and earthquake. Their distinct advantage over vertical piles is that they transmit the applied lateral loads p...

متن کامل

Modelling the Pullout Capacity of Marquee Ground Anchors Using Neurofuzzy Technique

Marquees are temporary light structures that are connected to the ground by tensile anchors to resist forces imposed by wind acting on the structure. Failures of such structures are not rare and have resulted in deaths and tens of thousands of dollars of damage. Consequently, an accurate estimation of the ultimate pullout capacity of ground anchors is essential; however, current methods for est...

متن کامل

Offshore anchor piles under mooring forces: centrifuge modeling

Offshore anchor piles are seafloor moorings that keep the position of floating structures during a harsh environment. These piles are usually subjected to a wide range of monotonic and cyclic lateral-to-oblique pullout forces. Centrifuge tests were carried out to study the behavior of offshore anchor piles under mooring forces in saturated dense sand. The tests were carried out at different loa...

متن کامل

The Behavior of Suction Bucket under Cyclic Loading in Saturated Lands

Numerical modeling was carried out to investigate the responses of suction bucket foundations under vertical cyclic loading. Numerical results were compared with centrifuge experiment results. Before the capacity of the model suction bucket to resist cyclic loading could be investigated, the static pullout capacities had to be determined. The buckets with different aspect ratio are investigated...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2013