Magnetic Particle Imaging (MPI): Experimental Quantification of Vascular Stenosis Using Stationary Stenosis Phantoms

نویسندگان

  • Sarah Vaalma
  • Jürgen Rahmer
  • Nikolaos Panagiotopoulos
  • Robert L Duschka
  • Jörn Borgert
  • Jörg Barkhausen
  • Florian M Vogt
  • Julian Haegele
چکیده

Magnetic Particle Imaging (MPI) is able to provide high temporal and good spatial resolution, high signal-to-noise ratio and sensitivity. Furthermore, it is a truly quantitative method as its signal strength is proportional to the concentration of its tracer, superparamagnetic iron oxide nanoparticles (SPIOs). Because of that, MPI is proposed to be a promising future method for cardiovascular imaging. Here, an interesting application may be the quantification of vascular pathologies like stenosis by utilizing the proportionality of the SPIO concentration and the MPI signal strength. In this study, the feasibility of MPI based stenosis quantification is evaluated based on this application scenario. Nine different stenosis phantoms with a normal diameter of 10 mm each and different stenoses of 1-9 mm and ten reference phantoms with a straight diameter of 1-10 mm were filled with a 1% Resovist dilution and measured in a preclinical MPI-demonstrator. The MPI signal intensities of the reference phantoms were compared to each other and the change of signal intensity within each stenosis phantom was used to calculate the degree of stenosis. These values were then compared to the known diameters of each phantom. As a second measurement, the 5 mm stenosis phantom was used for a serial dilution measurement down to a Resovist dilution of 1:3200 (0.031%), which is lower than a first pass blood concentration of a Resovist bolus in the peripheral arteries of an average adult human of at least about 1:1000. The correlation of the stenosis values based on MPI signal intensity measurements and based on the known diameters showed a very good agreement, proving the high precision of quantitative MPI in this regard.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computer-assisted analysis of three-dimensional MR angiograms.

The software tools required for postprocessing of magnetic resonance (MR) angiograms include the following functions: data handling, image visualization, and vascular analysis. A custom postprocessing software called Magnetic Resonance Angiography Computer Assisted Analysis (MARACAS) has been developed. This software combines the most commonly used three-dimensional visualization techniques wit...

متن کامل

Magnetic Particle / Magnetic Resonance Imaging: In-Vitro MPI-Guided Real Time Catheter Tracking and 4D Angioplasty Using a Road Map and Blood Pool Tracer Approach

PURPOSE In-vitro evaluation of the feasibility of 4D real time tracking of endovascular devices and stenosis treatment with a magnetic particle imaging (MPI) / magnetic resonance imaging (MRI) road map approach and an MPI-guided approach using a blood pool tracer. MATERIALS AND METHODS A guide wire and angioplasty-catheter were labeled with a thin layer of magnetic lacquer. For real time MPI ...

متن کامل

Comparative imaging study in ultrasound, MRI, CT, and DSA using a multimodality renal artery phantom.

PURPOSE A range of anatomically realistic multimodality renal artery phantoms consisting of vessels with varying degrees of stenosis was developed and evaluated using four imaging techniques currently used to detect renal artery stenosis (RAS). The spatial resolution required to visualize vascular geometry and the velocity detection performance required to adequately characterize blood flow in ...

متن کامل

Development of a noninvasive method to measure intravascular and intracardiac pressure differences using magnetic resonance imaging.

PURPOSE We developed a noninvasive method using magnetic resonance (MR) imaging to measure differences in intravascular and intracardiac pressure, and we investigated the feasibility of the method's use in a pulsatile flow phantom and human studies. METHODS We measured 3 velocity components using phase contrast MR imaging on a 1.5T MR scanner, used velocity data in Navier-Stokes equations to ...

متن کامل

[Evaluation of the detectability of vascular stenosis using non-contrast magnetic resonance angiography with various electrocardiographically-gated three-dimensional fast spin echo sequences].

Various three-dimensional fast spin echo (3D-FSE) sequences are used for non-contrast magnetic resonance angiography (MRA). Differences in the ability to detect vascular stenosis using these sequences, however, have not yet been evaluated. The purpose of this study is to evaluate the usefulness of each sequence for the detection of vascular stenosis by using a vascular phantom. The phantom cons...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017