Modeling of homogeneous cloned enzyme donor immunoassay.
نویسندگان
چکیده
One of the most widely used analytical techniques for sensitive detection of biologically and clinically significant analytes is the immunoassay. In recent years direct immunoprobes allowing label-free detection of the interaction between the antibody and the target analyte have proved their capabilities as fast, simple, and nevertheless highly sensitive methods. Cloned enzyme donor immunoassay (CEDIA) homogeneous assay is based on the bacterial enzyme beta-galactosidase, which has been genetically engineered into two inactive fragments, enzyme donor and enzyme acceptor. Reassociation of the fragments in the assay forms active enzyme, which acts on substrate to generate a colored product. A comprehensive kinetic model of CEDIA is developed to aid in understanding this method and to facilitate development of a truly homogeneous version, potentially applicable to a dipstick-type multianalyte point of care analytical device (ChemChip). Although the standard assay involves a two-step process, we also chose to model a single-combined process, which would be simpler to apply in a ChemChip device. From the modeling simulation, we obtain the time courses of the amounts of product and active enzyme, from which the dynamic ranges can be obtained as 10(-6)-10(-7) and 10(-5)-10(-7)M analyte concentration for two-step and single-combined processes under the conditions of the assumed parameters, respectively. A simple one-step immunoassay has the merit of reducing time and cost and has an improved dynamic range.
منابع مشابه
Microchip-based homogeneous immunoassay using a cloned enzyme donor.
We have realized a cloned enzyme donor immunoassay (CEDIA) on a microchip in 96 s. CEDIA is a homogeneous immunoassay, based on the bacterial enzyme beta-galactosidase, which was genetically engineered into two inactive fragments: an enzyme donor and an enzyme acceptor. A model analyte was theophylline, and the detectable concentration range was from 0 to 40 microg mL(-1). Our CEDIA using a mic...
متن کاملBuprenorphine detection in urine using liquid chromatography-high-resolution mass spectrometry: comparison with cloned enzyme donor immunoassay (ThermoFisher) and homogeneous enzyme immunoassay (immunalysis).
A sensitive liquid chromatographic-high-resolution mass spectrometric (LC-HR-MS) assay for buprenorphine and its urinary metabolites has been developed that requires minimal sample preparation. The results obtained have been compared with those given by (i) cloned enzyme donor immunoassay (CEDIA) and (ii) homogeneous enzyme immunoassay (HEIA) in the analysis of patient urines submitted for bupr...
متن کاملCloned enzyme donor immunoassay (CEDIA) for drugs-of-abuse screening.
Large numbers of specimens (5000-18,000) were screened for amphetamines, barbiturates, cocaine, marijuana, opiates, and phencyclidine by RIA (Roche), Emit II (Syva), and a new immunoassay, CEDIA (cloned enzyme donor immunoassay, Microgenics). All immunoassays performed equivalently for cocaine, opiates, and phencyclidine. All immunoassays detected the same amphetamine/methamphetamine-positive s...
متن کاملEvaluation of homogeneous enzyme immunoassay of serum thyroxine with the Gilford 3500 analyzer.
I evaluated homogeneous enzyme immunoassay (EMIT) of serum thyroxine with the Gilford 3500 analyzer. The samples are pretreated before quantitation on the Gilford 3500; the procedure thereafter is entirely mechanized. Forty-four samples may be analyzed per run. Precision and accuracy are good, and results correlate well with those by radioimmunoassay.
متن کاملPotential liabilities of gentamicin homogeneous enzyme immunoassay.
We report two potential liabilities of the homogeneous enzyme immunoassay for the determination of serum gentamicin. One is a considerable loss of precision and accuracy at the ends of the calibration curve, and the other is an apparent loss of gentamicin with storage at -60 degrees C.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical biochemistry
دوره 333 1 شماره