Fiber-optic biosensors based on fluorescence energy transfer.

نویسندگان

  • D Meadows
  • J S Schultz
چکیده

A new optical homogeneous biochemical method for the assay of glucose has been developed, based on fluorescence energy transfer between a glucose analog, dextran labeled with fluorescein isothiocyanate (FITC-dextran), and a glucose-receptor protein, Rhodamine-labeled Concanavalin A (Rh-ConA). When FITC-dextran binds to Rh-ConA in solution, and is light-activated, the FITC label transfers its absorbed energy to the Rhodamine label, which then emits light according to its own characteristic fluorescence spectrum. When glucose is added to this solution, the FITC fluorescence intensity increases as FITC-dextran is released from the Rh-ConA and is replaced by glucose. Thus it is possible to determine glucose concentrations directly from the level of FITC fluorescence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous fiber-optic sensor for chronic glucose monitoring in vivo.

We are developing a family of fiber-optic sensors called Sencils (sensory cilia), which are disposable, minimally invasive, and can provide in vivo monitoring of various analytes for several weeks. The key element is a percutaneous optical fiber that permits reliable spectroscopic measurement of chemical reactions in a nano-engineered polymeric matrix attached to the implanted end of the fiber....

متن کامل

An Evanescent Wave Fiber Optic Biosensor Based on Metal-Enhanced Fluorescence (MEF)

Fiber-optic biosensors play a significant role in the development of biosensors because they can provide miniaturized and lowcost systems. Recently, there have been explosive developments in the Metal-Enhanced Fluorescence (MEF) technology to favorably modify the spectral properties and to alleviate photo-physical constraints. We report the development of core/shell nanoparticles with the silve...

متن کامل

Amplification of the Signal Intensity of Fluorescence-Based Fiber-Optic Biosensors Using a Fabry-Perot Resonator Structure

Fluorescent biosensors have been widely used in biomedical applications. To amplify the intensity of fluorescence signals, this study developed a novel structure for an evanescent wave fiber-optic biosensor by using a Fabry-Perot resonator structure. An excitation light was coupled into the optical fiber through a laser-drilled hole on the proximal end of the resonator. After entering the reson...

متن کامل

Fluorescence intensity- and lifetime-based glucose sensing using glucose/galactose-binding protein.

We review progress in our laboratories toward developing in vivo glucose sensors for diabetes that are based on fluorescence labeling of glucose/galactose-binding protein. Measurement strategies have included both monitoring glucose-induced changes in fluorescence resonance energy transfer and labeling with the environmentally sensitive fluorophore, badan. Measuring fluorescence lifetime rather...

متن کامل

Enzyme-Based Fluorescent Biosensors and Their Environmental, Clinical and Industrial Applications

Enzyme-based fluorescence biosensors and their applications in environmental protection, medicine, and industry are described. Biosensors used in environmental protection measure toxicity effects. A chemical compound or group of compounds is detected by the recognition of molecules in the receptor layer and then by detecting a signal passing through the transducer layer. Biosensors are classifi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 35 2  شماره 

صفحات  -

تاریخ انتشار 1988