Broken Guidewire Fragment in the Radio-brachial Artery During Transradial Sheath Placement: Percutaneous Retrieval via Femoral Approach

نویسندگان

  • Jang-Young Kim
  • Junghan Yoon
  • Hyun-Sook Jung
  • Woo-Jea Kim
  • Byung-Su Yoo
  • Seung-Hwan Lee
  • Kyung-Hoon Choi
چکیده

A case in which a 0.014" wire was broken during the sheath placement in the radial artery for transradial coronary procedure is described here, and a successful retrieval of it using conventional methods is also described. Through the left femoral artery, the 6 Fr guiding catheter was advanced down to the tip of the broken wire at the brachial artery, and the distal part of the broken guidewire was captivated into the guiding catheter. By inflating the balloon catheter inside of the guiding catheter, seized broken guidewire between the inflated balloon and the guiding catheter was removed successfully by withdrawing the whole system en bloc.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...

متن کامل

Collateral arterial formation in a severed brachial artery causing difficult transradial access during percutaneous transluminal coronary angioplasty.

In this article, we describe about a 49-year-old patient who underwent percutaneous coronary intervention for a non-Q wave myocardial infarction via a transradial approach. The procedure was technically difficult, and the following fluroscopic image was obtained soon after radial arterial puncture (Figure 1). Further questioning revealed that the patient suffered a fall in 1975 while working in...

متن کامل

The Use of Protection Device in Landmark-wire Technique of Symptomatic Subclavian Artery Occlusion with Combined Approach via Trans-femoral vs. Trans-brachial Arteries: Technical note

PURPOSE Since we reported about a landmark technique to reopen an occluded subclavian artery, we have faced difficulty in using protection devices in the vertebral artery to protect against thromboembolism from the reversed steal phenomenon after angioplasty and stenting. Therefore, we are presenting an optimal solution in using a protection device while recanalizing the occluded subclavian art...

متن کامل

Safety and feasibility of the new 5 Fr Glidesheath Slender.

The aim of this study was to evaluate the safety and feasibility of the new 5 Fr Glidesheath Slender (GSS). The transradial (TR) approach has become popular because of several advantages, such as a reduced rate of vascular access site complications. However, because the radial artery is narrow, a limitation of TR access is the potential for artery spasm or occlusion. Studies of radial artery si...

متن کامل

Successful Revascularization to Right Coronary Artery by Percutaneous Coronary Intervention after Endovascular Therapy for Leriche Syndrome

A 69-year-old man with effort angina was admitted to our institution. Echocardiography showed poor left ventricular systolic function with akinesis of the anterior wall and severe hypokinesis of the inferior wall. We performed coronary angiography, which revealed two diseased vessels including chronic total occlusion in the left anterior descending artery and severe stenosis in the right corona...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 46  شماره 

صفحات  -

تاریخ انتشار 2005