Evaluation of a Rapid Point of Care Test for Detecting Acute and Established HIV Infection, and Examining the Role of Study Quality on Diagnostic Accuracy: A Bayesian Meta-Analysis
نویسندگان
چکیده
INTRODUCTION Fourth generation (Ag/Ab combination) point of care HIV tests like the FDA-approved Determine HIV1/2 Ag/Ab Combo test offer the promise of timely detection of acute HIV infection, relevant in the context of HIV control. However, a synthesis of their performance has not yet been done. In this meta-analysis we not only assessed device performance but also evaluated the role of study quality on diagnostic accuracy. METHODS Two independent reviewers searched seven databases, including conferences and bibliographies, and independently extracted data from 17 studies. Study quality was assessed with QUADAS-2. Data on sensitivity and specificity (overall, antigen, and antibody) were pooled using a Bayesian hierarchical random effects meta-analysis model. Subgroups were analyzed by blood samples (serum/plasma vs. whole blood) and study designs (case-control vs. cross-sectional). RESULTS The overall specificity of the Determine Combo test was 99.1%, 95% credible interval (CrI) [97.3-99.8]. The overall pooled sensitivity for the device was at 88.5%, 95% [80.1-93.4]. When the components of the test were analyzed separately, the pooled specificities were 99.7%, 95% CrI [96.8-100] and 99.6%, 95% CrI [99.0-99.8], for the antigen and antibody components, respectively. Pooled sensitivity of the antibody component was 97.3%, 95% CrI [60.7-99.9], and pooled sensitivity for the antigen component was found to be 12.3%, 95% (CrI) [1.1-44.2]. No significant differences were found between subgroups by blood sample or study design. However, it was noted that many studies restricted their study sample to p24 antigen or RNA positive specimens, which may have led to underestimation of overall test performance. Detection bias, selection (spectrum) bias, incorporation bias, and verification bias impaired study quality. CONCLUSIONS Although the specificity of all test components was high, antigenic sensitivity will merit from an improvement. Besides the accuracy of the device itself, study quality, also impacts the performance of the test. These factors must be kept in mind in future evaluations of an improved device, relevant for global scale up and implementation.
منابع مشابه
ارزش تشخیصی لاکتات دهیدروژناز و کراتینین مایع مهبلی در تشخیص پارگی زودرس پرده های جنینی
Background and purpose: Premature rupture of membrane (PRÔM) is a common and challenging issue in obstetrics. Ëarly diagnosis of PRÔM and the consequent infection has a pivotal role in proper management of patients. The detection of PRÔM is easier in a case with visible vaginal fluid, but is difficult when trivial amount of vaginal fluid presents. Ïn this study, we aimed to assess the diagnos...
متن کاملImproving the Quality of Diagnostic Studies Evaluating Point of Care Tests for Acute HIV Infections: Problems and Recommendations
The diagnosis of acute human immunodeficiency virus (HIV) infection (AHI) plays a unique role in preventing the spread of HIV and ending the epidemic. Acutely infected individuals are thought to contribute substantially to forward transmissions of HIV; however, diagnosing AHI in resource-limited settings has proven to be a challenge. While fourth generation antigen-antibody combination assays h...
متن کاملStudy on the accuracy of milk amyloid A test and other diagnostic methods for identification of milk quality
Bulk tank somatic cell count (BTSCC) is a gold standard test for identification of milk quality, but its results are influenced by several interventional factors. Recently, application of acute phase proteins and especially milk amyloid A (MMA) has been considered as accurate parameters for milk quality study. The current research was done to evaluate the accuracy of MMA, BTSCC, fat, protein an...
متن کاملDetection of acute HIV infection: a field evaluation of the determine® HIV-1/2 Ag/Ab combo test.
BACKGROUND Most human immunodeficiency virus (HIV) point-of-care tests detect antibodies (Ab) but not p24 antigen (Ag) or RNA. In the absence of antibodies, p24 antigen and RNA typically indicate acute HIV infection. We conducted a field evaluation of the Determine® HIV-1/2 Ag/Ab Combo rapid test (Combo RT). METHODS The antigen portion of the Combo RT (for acute HIV infection) was compared wi...
متن کاملHIV Rapid Diagnostic Test Inventories in Zambézia Province, Mozambique: A Tale of 2 Test Kits
Background The first pillar of the UNAIDS 90-90-90 goal seeks to accurately identify persons living with HIV (PLHIV), a process that is predicated on facilities having the necessary HIV tests available to perform the task. In many rural settings, the identification of PLHIV is accomplished through a two-step process involving the sequential use of 2 separate rapid diagnostic tests (RDTs)....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2016