GIM, simulation software of meal glucose-insulin model.

نویسندگان

  • Chiara Dalla Man
  • Davide M Raimondo
  • Robert A Rizza
  • Claudio Cobelli
چکیده

BACKGROUND A simulation model of the glucose-insulin system in normal life conditions can be very useful in diabetes research, e.g., testing insulin infusion algorithms and decision support systems and assessing glucose sensor performance and patient and student training. A new meal simulation model has been proposed that incorporates state-of-the-art quantitative knowledge on glucose metabolism and its control by insulin at both organ/tissue and whole-body levels. This article presents the interactive simulation software GIM (glucose insulin model), which implements this model. METHODS The model is implemented in MATLAB, version 7.0.1, and is designed with a windows interface that allows the user to easily simulate a 24-hour daily life of a normal, type 2, or type 1 diabetic subject. A Simulink version is also available. Three meals a day are considered. Both open- and closed-loop controls are available for simulating a type 1 diabetic subject. RESULTS Software options are described in detail. Case studies are presented to illustrate the potential of the software, e.g., compare a normal subject vs an insulin-resistant subject or open-loop vs closed-loop insulin infusion in type 1 diabetes treatment. CONCLUSIONS User-friendly software that implements a state-of-the-art physiological model of the glucose-insulin system during a meal has been presented. The GIM graphical interface makes its use extremely easy for investigators without specific expertise in modeling.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intelligent blood glucose control in diabetic patients: design and simulation of an artificial pancreas

Background: Diabetes mellitus (DM) is a common chronic disease with diverse complications. About 10% of the earth's population suffer from this disease. For smart control of the blood glucose in DM patients, an artificial pancreas was designed and simulated by a predictive sliding mode controller considering the time delay of insulin effect. Method: In this method, one of the time-delay glucos...

متن کامل

The Effects of 6 Isocaloric Meals Pattern on Blood Lipid Profile, Glucose, Hemoglobin A1c, Insulin and Malondialdehyde in Type 2 Diabetic Patients: A Randomized Clinical Trial

Background: The present clinical trial study aims at investigating the effect of daily energy intake in 6 isocaloric meals in comparison with the current meal pattern (3 meals and 2 small snacks per day) on type 2 diabetes risk markers in diabetes during 3-month period. Methods: Eighty four type 2 diabetes patients were randomly divided into 6 isocaloric meal diet or a balanced diet (3 meals an...

متن کامل

Study of the effect of meal frequency in non-insulin dependent diabetic patients

  the purpose of this semi-experimental,cross-over and perspective study was to investigate the effect of the number of the meals on fasting serum,colestrol,triglyceride,glucose,and serum glucose at time intervals of 0.5,1,1.5 and 2 hours after eating a standard breakfast(BTT) included 125g of taftoon bread,cheese 40g,50g of 2.5% milk which contains 470kcal of energy,75g of carbohydrate,20g of...

متن کامل

Effects of antihypertensive therapy on glucose and insulin metabolism and on left ventricular mass: A randomized, double-blind, controlled study of 21 obese hypertensives.

BACKGROUND Glucose and insulin levels are associated with left ventricular mass (LVM) in insulin-resistant individuals. Antihypertensive drugs have different effects on glucose and insulin metabolism (GIM) and on LVM. To evaluate whether the effects of antihypertensive therapy on LVM are associated with its effects on GIM, we compared the effects of atenolol and perindopril on these parameters ...

متن کامل

A Closed-loop Artificial Pancreas based on MPC: human-friendly identification and automatic meal disturbance rejection

Abstract: Type 1 diabetes is characterized by a lack of insulin production from the pancreas, causing high blood glucose concentrations and requiring external insulin infusion to regulate blood glucose. A novel procedure of “human-friendly” identification testing using multisine inputs is developed to estimate suitable models for use in an artificial pancreas. A human-friendlymultisine input si...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 1 3  شماره 

صفحات  -

تاریخ انتشار 2007