Dosimetry of the Very Weak X-radiation Generated in Television Receivers and X-ray Diffraction Apparatus
ثبت نشده
چکیده
With many kinds of apparatus in which electron tubes are operated at high voltages, the possiblepresence of very weak, soft Xvradiation, (i.e. Xradiation of low penetrating power) in the neighbourhood must be given due consideration. The question arises in such apparatus as X-ray diffraction equipment, formerly found only in research laboratories but now widely used industrially in inspection and production departments. Television receivers, too, can emit X-rays, for inmodern largescreen sets the accelerating voltage for the electron beam in the picture tube can be as high as 20 kV at a beam current up to 0.2 mA. Fortunately this X-radiation is so soft that it can be attenuated to harmless intensities by simple means, for example by the 6 mm thick glass shield over the viewing screen, which is needed in any case as proteetion against implosion of the tube. Nevertheless it is necessary during manufacture to make dosimetrie tests to ensure that the intensity of the radiation at the outside of the set in no way endangers the user. The' International Commission for Radiological Proteetion 1) has recommended that the dose rate at the outside surface of home television receivers should not exceed 2 milliröntgens per hour (2 mr/h or 0.6 IJ-r/sec). In the future the limit will probably be set lower still, in order to preclude all possibility of genetic hazards. This possible lowering of the limit has been allowed for in the design of the dosimetrie apparatus described in this article. . In the case of X-ray diffraction apparatus, the requirements s.regarding the maximum permissible dose rate outside the useful" X-ray beam are less severe, such apparatus being used by so very small a section of the population that genetic considerations do not arise and only the norms for individual proteetion need be applied. For the industrial use of X-ray equipment the recommended maximum permissible dose rate 'outside the useful beam is 6 mr/h. The dose rate of 'very weak, soft X-radiation, such as that from television receivers, can be checked ~th Geiger-Müller counter tubes :fitted with a window ofthin mica (approx. 15 IJ-).Such tubes are
منابع مشابه
Dosimetry of Occupational Radiation around Panoramic X-ray Apparatus
Background: Panoramic imaging is one of the most common imaging methods in dentistry. Regarding the side-effects of ionizing radiation, it is necessary to survey different aspects and details of panoramic imaging. In this study, we compared the absorbed x-ray dose around two panoramic x-ray units: PM 2002 CC Proline (Planmeca, Helsinki, Finland) and Cranex Tome (Soredex, Helsinki, Finland).<br ...
متن کاملImpact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملامکان سنجی بکارگیری عناصر نیمه هادی از نوع PIN به منظور دزیمتری پرتوهای ایکس تشخیصی
Knowing patient exact dose during radiological activities is considered as one of the main principles to decrease radiation-induced dangers which are not really necessary and affect a great deal of people. In this respect, in recent years many extensive studies have been done on types of photodiodes and production of X-ray detectors using semiconductor elements. Since these elements are not ver...
متن کاملX-ray spectra calculation for different target-filter of mammograms using MCNP Code
ABSTRACTBackground: An electron beam generated X-ray spectrum consists of characteristic X-ray and continuous bermsstrahlung. The aim of this research is calculating and comparing X-ray spectra for different target filter of mammograms. Materials and Methods: Monte Carlo is a very powerful tool to simulate a series of different target-filter assembly in order to calculate the X-ray spectra. MC...
متن کاملاستفاده از شتابگر الکترونی MeV 10 برای تولید تابش چرنکوف درناحیه پرتوایکس نرم
Cherenkov radiation is generated when relativistic charged particles move in a medium with refractive index larger than unity. Although, the refractive index is generally smaller than unity in X-ray region, in the vicinity of atomic absorption edges, the refractive index may exceed unity and Cherenkov radiation can be generated in soft X-ray region with a narrow band width. In this paper, the s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2014