Analysis of the Vacuum Arc Interruption Process in Aviation Intermediate-Frequency Power Supply Systems

نویسندگان

  • Yuan Jiang
  • Jianwen Wu
  • Mingxuan Chen
  • Wenlei Huo
چکیده

In this paper, we present our research into the interruption performance of vacuum circuit breakers in aviation intermediate-frequency (360 Hz to 800 Hz) power supply systems. Intermediate-frequency vacuum arc experiments were carried out in interrupters with a diameter of 41 mm and CuCr50 alloy contact material. The results show that, as the frequency and peak value of the current increase, both the peak value and rise rate of the intermediate-frequency vacuum arc voltage also increase, and the interruption ability decreases. However, compared to the power frequency current at the same value, the erosion of the contacts is weaker over a shorter arc period. When the vacuum arc reignites, metal droplets are emitted from the contacts. The drive force is from the center of the contact to the edge. If the density of the plasmas and metal vapors and the number of the metal droplets reaches a certain level, the arc may break down, which will cause the interruption to fail.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation on the Thermal Process of Anode in Vacuum Arc

Anode activity in vacuum arc plays a very important role in both characteristics of vacuum arc and the interruption capacity of vacuum interrupters. In this paper, the transient thermal processes of anode in vacuum arc in a half of arc current cycle with frequency of 50 Hz are simulated by finite element analysis software, ANSYS. Some important phenomena of anode, e.g., the melt and solidificat...

متن کامل

Arc extinction characteristics in power supply frequencies from 50 Hz to 1 MHz

It is well-known that arcing phenomena at the break of contacts affect seriously the reliability and lifetime of contacts. Therefore, many papers have reported arc duration, arc extinction current and other characteristics. Recently, in mobile communication application an electro-mechanical switch is said to be superior to a semiconductor switch in insertion loss and isolation, and a RF (radio ...

متن کامل

Method and apparatus for automatically re-igniting vacuum arc plasma source

An apparatus and method are disclosed whereby if the arc in a DC or long-pulse AC vacuum arc plasma process (eg in vacuum deposition) starts to extinguish, this is automatically detected and a reignition process is activated. Detection of a tendency for the arc to extinguish is detected by monitoring the main power supply voltage, which will increase if the arc is extinguished. References Cited...

متن کامل

Presenting a New Model for Bank’s Supply Chain Performance Evaluating with DEA Solution Approach

Data Envelopment Analysis (DEA) is a method for measuring the efficiency of peer decision making units (DMUs) with multiple inputs and outputs. The traditional DEA treats decision making units under evaluation as black boxes and calculates their efficiencies with first inputs and last outputs. This carries the notion of missing some intermediate measures in the process of changing the inputs to...

متن کامل

Design and Simulation of a New DC Power Supply Based on Dual Bridge Matrix Converter

A conventional high power DC power supply systems consist of a three-phase diode rectifier followed by a high frequency converter to supply loads at regulated DC voltage. These rectifiers draw significant harmonic currents from the utility, resulting in poor input power factor. In this paper, a DC power supply based on dual-bridge matrix converter (DBMC) with reduced number of switches is p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017