The first report on intermediate-term outcome of Ex-PRESS® glaucoma filtration device implanted under scleral flap in Japanese patients
نویسندگان
چکیده
PURPOSE This paper compares the outcomes of the Ex-PRESS(®) Glaucoma Filtration Device (Alcon, Fort Worth, TX) implant observed in Japanese patients for 1 year with those of patients undergoing trabeculectomy. PATIENTS AND METHODS The subjects comprised ten eyes of ten cases with open-angle glaucoma for which filtration surgery using Ex-PRESS (P-50) was performed by one operator from February 2008 and observed for at least 1 year (Ex-PRESS Group), and eleven eyes of eleven cases for which trabeculectomy was performed by the same operator (TE Group). For both groups, mitomycin C was used and a scleral flap was created after a fornix-based incision of the conjunctiva. RESULTS Hypotony and choroidal detachment were observed as early postoperative complications during a 1-week period in one-third of the cases in the TE Group, and failing vision in about 45%, while these were seen in fewer cases in the Ex-PRESS Group. No significant difference in intraocular pressure (IOP) was observed during the period, but IOP variations on the day following the surgery were obviously narrower in the Ex-PRESS Group than in the TE Group. Visual acuity was significantly poorer from 1 week to 3 months in the TE Group while it was stable in the Ex-PRESS Group. The Ex-PRESS Group had fewer cases of laser suture lysis and fewer administrations of glaucoma eyedrop, and no cases of progression in the stage of visual field defect. CONCLUSION Filtration surgery using the Ex-PRESS is unlikely to cause early complications in Japanese patients. Similarly to the trabeculectomy, the intermediate-term control of IOP showed favorable results.
منابع مشابه
Five-year extension of a clinical trial comparing the EX-PRESS glaucoma filtration device and trabeculectomy in primary open-angle glaucoma
BACKGROUND This study compared the efficacy of the EX-PRESS(®) glaucoma filtration device and trabeculectomy in primary open-angle glaucoma up to five years after surgery. METHODS Patients from a previously reported randomized, open-label, parallel-arm clinical trial in which 78 patients received either the EX-PRESS glaucoma filtration device or underwent a trabeculectomy were followed for up...
متن کاملClinical experience with Ex-press Mini Glaucoma Shunt implantation.
In this prospective study we wanted to report our experience and to evaluate the efficacy and safety of Ex-press Mini-Glaucoma Shunt implantation under a superficial scleral flap, as a newly and improved surgical technology in a treatment of POAG (Primary open-angle glaucoma) and refractory glaucoma. 44 eyes (35 patients) underwent an implantation of Ex-Press Mini Glaucoma Shunt. We had 21 pati...
متن کاملSurgical outcomes of the Ex-PRESS glaucoma filtration device in African American and white glaucoma patients
PURPOSE To compare the surgical outcomes of the Ex-PRESS glaucoma filtration device in African American and white glaucoma patients. DESIGN Retrospective comparative case series. METHODS This was a comparative case series of 36 eyes of 36 African Americans and 43 eyes of 43 whites that underwent placement of the Ex-PRESS glaucoma filtration device under a partial-thickness scleral flap for ...
متن کاملEvaluation of the Ex-PRESS(®) P-50 implant under scleral flap in combined cataract and glaucoma surgery.
AIM To evaluate the efficacy and safety of glaucoma drainage device Ex-PRESS(®) P-50 for combined cataract surgery and glaucoma. METHODS Patients having cataract and open angle glaucoma or patients with open advanced glaucoma which needed two or more antiglaucoma medications were included. Combined cataract surgery and glaucoma with Ex-PRESS(®) P-50 model placed under scleral flap was perform...
متن کاملucoma: advances in penetrating glaucoma surgery
Current Opinion in Ophthalmology 2008, 19:149–154 Purpose of review Despite late modifications and enhancements, traditional penetrating glaucoma surgery is not without complications and is reserved for patients in whom pharmacologic treatment and/or laser trabeculoplasty do not suffice to control the intraocular pressure This article critically reviews recent advances in penetrating glaucoma s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 5 شماره
صفحات -
تاریخ انتشار 2011