Three-dimensional, non-destructive visualization of vertical root fractures using flat panel volume detector computer tomography: an ex vivo in vitro case report.

نویسندگان

  • C Hannig
  • C Dullin
  • M Hülsmann
  • G Heidrich
چکیده

AIM To detect and to visualize radiographically vertical root fractures in extracted teeth with a prototype of a novel, high resolution, three-dimensional flat panel volume detector computer tomograph (FD-VCT) system. SUMMARY Five teeth with root fillings and clinical symptoms such as fistulas and isolated periodontal pockets of 8 mm or more were extracted after dental radiography indicating lateral or periapical lesions. Vertical root fractures or cracks were suspected because of the symptoms and clinical findings were evident after extraction in all cases but fracture lines were not visible on routine dental radiographs acquired before extraction. The extracted teeth were explored with a prototype of a FD-VCT. Using the FD-VCT, in all cases vertical root fractures or crack lines could be detected clearly in different views, depiction-modes and cross-sections at a spatial resolution of 140 microm. The evaluation of the fracture lines and teeth could be performed in three-dimensional views. The FD-VCT findings were confirmed by detailed inspection of the extracted teeth. KEY LEARNING POINTS The FD-VCT is an innovative diagnostic tool for non-destructive, three-dimensional evaluation of extracted teeth in pre-clinical and experimental studies. The FD-VCT allows precise visualization and evaluation of vertical root fractures or cracks in extracted teeth. Clinical application of the system may be possible if technical modifications reduce the exposure dose: the high resolution detector systems of the FD-VCT should be combined with radiation systems that focus the radiation to the area of interest.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies

Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...

متن کامل

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

Three Dimensional Artifact Free Visualization of Different Metallic Intervertebral Disc Spacers With Flat Panel Detector Volume CT (FD-VCT): A Comparative Cadaveric Spine Study

Image quality and implant detectability by conventional imaging methods are suboptimal for perioperative spinal diagnostics, primarily limited by implant-related artifacts. This preclinical experimental study aimed to evaluate the imaging quality of two different metallic intervertebral spacers used as stand alone cages examined by flatpanel detector-based volumetric computed tomography (FD-VCT...

متن کامل

Three-dimensional imaging and cone beam volume CT in C-arm angiography with flat panel detector.

We evaluated a new 3D angiography system with a flat panel detector (FPD) for its capabilitiy to acquire volume sets during a single rotation scan and to reconstruct high spatial resolution three-dimensional and cross sectional images, namely cone beam volume computed tomography (CBVCT) images. Present status of the technique, advantages and potential applications are discussed.

متن کامل

In vivo dose verification using using an amorphous silicon flat panel-type imager (a-Si EPIDs)

Introduction: Electronic portal imaging devices (EPIDs) could be used to dose verification of radiotherapy treatment plans. In vivo dose verification is performed to reduce differences found between dose delivered to the patient and the prescribed dose. The aim of this study was to perform a fast and efficient technique for the verification of delivered dose to the patient usin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • International endodontic journal

دوره 38 12  شماره 

صفحات  -

تاریخ انتشار 2005