An in vitro evaluation of an automatic clamp for use with centrifugal pumps.
نویسندگان
چکیده
The risk of air emboli is a concern for all perfusionists. A new clamping device for use with centrifugal pumps is designed to clamp both the arterial and venous lines at the first indication of air or retrograde flow, thereby allowing the perfusionist to evaluate the situation and correct the problem before entraining air into the arterial pump head. After evaluating this device in our lab, we conclude that this new safety device should be added to the heart lung machine by all perfusionists using centrifugal pumps.
منابع مشابه
Method of Evaluation of Efficiency Improvement Potential for District Heating Systems with Focus on Variable Speed Centrifugal Pumps
The goal of this research is the derivation of method for evaluation of efficiency improvement potential for district heating systems with focus on variable speed centrifugal pump. The effectiveness of the usage of the proportional pressure control is compared with the constant pressure control. This is why, energy calculation analyses have been realized for variable speed centrifugal pumps, an...
متن کاملImpeller and volute design and optimization of the centrifugal pump with low specific speed in order to extract performance curves
Now a day centrifugal pumps are vital components of industries. Certainly, one of the most important specifications of centrifugal pumps are the performance curves. In the present work, performance curves of a centrifugal pumps are obtained by Computational fluid dynamics (CFD) and as an outcome, CFD results compare by practical curves. At the first step impeller and volute are designed with tw...
متن کاملTheoretical, Scientific and Practical Aspects of the Basic Stages of Cad Cam Designing of Centrifugal Pumps
Many theoretical and practical problems arise at different stages of the design/manufacturing process during development of a pump. The experience obtained in pump development proves that the quality of a pump depends on many factors, which should he satisfied to receive good results. At the same time, the theory of engineering design principles exists, which is applicable to designing various ...
متن کاملDevelopment of Linguistic Rules Diagnosis of Failure in Centrifugal Pump for Use in Expert System
Operational failures in centrifuge pumps could be hydraulic or mechanical. However, most of these mechanical and hydraulic failures are connected cause of their operational nature and finding the right cause is due to considering numerous mechanical and hydraulic signs and parameters in pumps. On the other hand, due to non-linear and fluctuant behavior of pumps in the matter of time and not pre...
متن کاملDevelopment of Linguistic Rules Diagnosis of Failure in Centrifugal Pump for Use in Expert System
Operational failures in centrifuge pumps could be hydraulic or mechanical. However, most of these mechanical and hydraulic failures are connected cause of their operational nature and finding the right cause is due to considering numerous mechanical and hydraulic signs and parameters in pumps. On the other hand, due to non-linear and fluctuant behavior of pumps in the matter of time and not pre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The journal of extra-corporeal technology
دوره 29 3 شماره
صفحات -
تاریخ انتشار 1997