Erratum to: A randomized prospective controlled trial comparing the laryngeal tube suction disposable and the supreme laryngeal mask airway: the influence of head and neck position on oropharyngeal seal pressure
نویسندگان
چکیده
Erratum In the version of this article that was published on PubMed Central [1] the author’s name “Gustavo Garcia Fornari” was formatted incorrectly in the XML mark up and appeared incorrectly on PubMed Central. In the Mark up, “Gustavo Garcia” was added as the Given Name and “Fornari” was the Family Name, but the Family Name should have been “Garcia Fornari” and the Given Name “Gustavo”. Due to this error, the author’s name was incorrectly formatted in PubMed Central as “Fornari GG” and not as “Garcia Fornari G”. The authors name is correct on the BioMed Central website.
منابع مشابه
A randomized prospective controlled trial comparing the laryngeal tube suction disposable and the supreme laryngeal mask airway: the influence of head and neck position on oropharyngeal seal pressure
BACKGROUND The Laryngeal Tube Suction Disposable (LTS-D) and the Supreme Laryngeal Mask Airway (SLMA) are second generation supraglottic airway devices (SADs) with an added channel to allow gastric drainage. We studied the efficacy of these devices when using pressure controlled mechanical ventilation during general anesthesia for short and medium duration surgical procedures and compared the o...
متن کاملComparison of Five 2nd-Generation Supraglottic Airway Devices for Airway Management Performed by Novice Military Operators
OBJECTIVES Five different second-generation supraglottic airway devices, ProSeal LMA, Supreme LMA, i-gel, SLIPA, and Laryngeal Tube Suction-D, were studied. Operators were inexperienced users with a military background, combat lifesavers, nurses, and physicians. METHODS This was a prospective, randomized, single-blinded study. Devices were inserted in the operating room in low light condition...
متن کاملLimitation of Laryngeal Mask Airway Usage in Open-Neck Procedure
I read the manuscript entitled “Case Report of An Open Neck Procedure Complication Associated with Laryngeal Mask Airway Use” by Subramaniam T et al. This is a valuable manuscript describing iatrogenic complications during level-2 cervical lymph node biopsy, in which the airway is managed with laryngeal mask airway (LMA). During the procedure, the surgeon realized that the mass was actually the...
متن کاملComparing the Effect of Laryngeal Mask Airway And Endotracheal Tube Insertion on Intraocular Pressure in Cataract Surgery
Background and purpose: The method of anesthesia affects intraocular pressure (IOP), especially general anesthesia which is sometimes administered with endotracheal tube (ETT) insertion. The aim of this research was to compare the effect of laryngeal mask airway (LMA) and ETT on intraocular pressure in cataract surgery. Materials and methods: In a single blind randomized clinical trial, 61 pat...
متن کاملComparison of the Incidence of Sore Throat and Hemodynamic Changes in Airway Management by Macintosh, Glideoscope Laryngoscope and Laryngeal Mask Airway Techniques: Randomized Controlled Trial
Background: Studies have shown that postoperative sore throat is the most common complication of tracheal intubation, However, the actual incidence and extent of it are not well documented. Objective: The aim of this study was to evaluate and compare the incidence of sore throat and hemodynamic Changes in Macintosh, Glidescope Laryngoscope and laryngeal mask airway techniques in elective surg...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2016