MAgnitude and PHase Thresholding (MAPHT) of noisy complex-valued magnetic resonance images.
نویسندگان
چکیده
It is often desirable to separate voxels that contain signal from tissue along with measurement noise from those that contain purely measurement noise. Generally, this separation called thresholding utilizes only the magnitude portion of the images. Recently, methods have been developed that utilize both the magnitude and phase for thresholding voxels. This manuscript is an extension previous work and uses the bivariate normality of the real and imaginary values with phase coupled means. A likelihood ratio statistic is derived that simplifies to a more familiar form that is F-distributed in large samples. It is shown that in small samples, critical values from Monte Carlo simulation can be used to threshold this statistic with the proper Type I and Type II error rates. This method is applied to susceptibility weighted magnetic resonance images and shown to produce increased tissue contrast.
منابع مشابه
De-noising, phase ambiguity correction and visualization techniques for complex-valued ICA of group fMRI data
Analysis of functional magnetic resonance imaging (fMRI) data in its native, complex form has been shown to increase the sensitivity both for data-driven techniques, such as independent component analysis (ICA), and for model-driven techniques. The promise of an increase in sensitivity and specificity in clinical studies, provides a powerful motivation for utilizing both the phase and magnitude...
متن کاملThresholding complex magnetic resonance images using magnitude and Phase
It is often desirable to separate voxels that contain signal from tissue along with measurement noise from those that contain purely measurement noise. Generally this separation called thresholding utilizes only the magnitude portion of the images. Recently methods have been developed that utilize both the magnitude and phase for thresholding voxels [Pandian D, Ciulla C, and Haacke EM, Jiang J,...
متن کاملMRI Noise Reduction via Phase Correction and Wavelet-Domain Filtering
Post-acquisition processing of MRI images to remove noise can potentially improve their diagnostic value. Currently there are many suggested wavelet thresholding algorithms for denoising MRI data with most of them focused on magnitude-reconstructed images. An alternate approach is to correct phase errors in the image and then take the real value of each pixel as the grayscale intensity. We pres...
متن کاملA new susceptibility-weighted image reconstruction method for the reduction of background phase artifacts.
PURPOSE To significantly reduce the background phase effects, especially at the air-tissue interface, and to enhance the desirable local structures of veins in susceptibility-weighted imaging. METHODS In the proposed reconstruction method called Magnitude of Complex Filtering, a complex-valued magnetic resonance image is acquired using a flow-compensated high-resolution 3D gradient-echo seque...
متن کاملBlood Vessel Segmentation in Complex-Valued Magnetic Resonance Images with Snake Active Contour Model
Accurate blood vessel segmentation plays a crucial role in non-invasive blood flow velocity measurement based on complex-valued magnetic resonance images. We propose a specific snake active contour model-based blood vessel segmentation framework for complex-valued magnetic resonance images. The proposed framework combines both magnitude and phase information from a complex-valued image represen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance imaging
دوره 27 9 شماره
صفحات -
تاریخ انتشار 2009