Noninvasive assessment of aqueous humor turnover in the mouse eye.

نویسندگان

  • Marcel Y Avila
  • Claire H Mitchell
  • Richard A Stone
  • Mortimer M Civan
چکیده

PURPOSE To develop a noninvasive test for monitoring changes in aqueous humor turnover in the mouse eye. METHODS After topical instillation of fluorescein, the rate of decay of fluorescence from aqueous humor and cornea was monitored in Black Swiss, C57 Bl6, and DBA 2J mice with a microscope equipped with epifluorescence and a charge-coupled device (CCD) camera. RESULTS The rate of decay of fluorescence was identical in right and left eyes over an approximately 70-minute measurement period. The rate of decay was similar in normal mice aged 2 and 18 months. Pilocarpine and latanoprost, known to enhance aqueous humor outflow in humans, accelerated the decay of fluorescence. Levobunolol, known to inhibit aqueous humor inflow in humans, slowed decay. Dimethylamiloride, an inhibitor of the Na(+),H(+) exchanger that is known to act on cultured cells of both the ciliary epithelium and trabecular meshwork and to lower mouse intraocular pressure (IOP), enhanced decay. DBA 2J mice, in which secondary glaucoma develops, displayed a slower decay of fluorescence at 18 months of age than age-matched unaffected animals. CONCLUSIONS Monitoring decay of fluorescence provides a noninvasive index of aqueous humor dynamics in the mouse eye that facilitates study of ocular hypotensive drugs and mouse models of glaucoma. Coupled with knowledge of IOP, it permits semiquantitative conclusions about the relative roles of aqueous humor inflow and outflow in conditions with altered IOP. Based on this approach, dimethylamiloride appears to lower mouse IOP primarily by enhancing outflow of aqueous humor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aqueous humor dynamics in mice.

PURPOSE To assess aqueous humor dynamics in mouse eyes. METHODS Aqueous humor dynamics of NIH Swiss White mouse were assessed with an injection and aspiration system, using fine glass microneedles. Intraocular pressure (IOP) was measured by a microneedle connected to a pressure transducer. Episcleral venous pressure (EVP) was measured by gradually lowering intracameral pressure until blood re...

متن کامل

Aqueous humor turnover rates in the cat. I. Effect of acetazolamide.

Aqueous humor turnover in the cat eye determined by intracameral injection of inulin*C was found to be 2.1 per cent per minute, a value which is in close agreement with that reported for other species. The inhibition of aqueous humor formation induced by acetazolamide was dose dependent bid the quantities required were much higher than those reported necessary to lower the eye pressure. The dat...

متن کامل

Aqueous humor turnover rates in the cat. II. Effect of ouabain and chlorothiazide.

.he ability of the cardiac glycosides, ouabain and digoxin, to lower eye pressure-' '' '-• has been ascribed to a primary inhibition of aqueous humor inflow. In the cat, which is the experimental animal of this study, the effect of ouabain on aqueous humor inflow is not clear. The previous report, which indicated that aqueous humor formation of the cat was decreased by ouabain, was based upon r...

متن کامل

Noninvasive monitoring of Pirenoxine Sodium concentration in aqueous humor based on dual-wavelength iris imaging technique

We present a noninvasive method of detecting substance concentration in the aqueous humor based on dual-wavelength iris imaging technology. Two light sources, one centered within (392 nm) and the other centered outside (850 nm) of an absorption band of Pirenoxine Sodium, a common type of drugs in eye disease treatment, were used for dual-wavelength iris imaging measurement. After passing throug...

متن کامل

Two-photon imaging of the mouse eye.

PURPOSE To image the conventional aqueous outflow pathway and adjacent structures within the intact enucleated mouse eye using a noninvasive microscopy technique. METHODS Two-photon microscopy (2PM) techniques, including two-photon autofluorescence (2PAF) and second harmonic generation (SHG), were used to obtain images of the trabecular meshwork (TM) region within an intact mouse eye. Cardiac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 44 2  شماره 

صفحات  -

تاریخ انتشار 2003