Changes in intraocular pressure values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology tonometer (CST) in the early phase after small incision lenticule extraction (SMILE)
نویسندگان
چکیده
BACKGROUND Corneal biomechanical properties are always compromised after corneal refractive surgeries thus leading to underestimated intraocular pressure (IOP) that complicates the management of IOP. We investigated the changes in postoperative baseline of IOP values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology (CST) in the early phase after small incision lenticule extraction (SMILE). METHODS Twenty-two eyes (-6.76 ± 1.39D) of 22 moderate and high myopes, (28.36 ± 7.14 years, 12 male and 10 female) were involved in this prospective study. IOP values were measured using a non-contact tomometer (NCT-IOP), an ocular response analyzer (corneal-compensated IOP, IOPcc and Goldmann-correlated IOP, IOPg) and a Corvis scheimpflug technology tonometer (CST-IOP) preoperatively, at 20 min and 24 h, postoperatively. Repeated measures analysis of variance (RM-ANOVA), Pearson's correlation analysis and multiple linear regression models (stepwise) were performed. Cut-off P values were 0.05. RESULTS Except for IOPcc, NCT-IOP, IOPg, and CST-IOP values significantly decreased after SMILE procedure (All P values <0.05). ΔCCT, as well as ΔMRSE and ΔKm, did not significantly correlated with ΔNCT-IOP, ΔIOPcc, ΔIOPg or ΔCST-IOP, (all P values >0.05). Multiple linear regression models (stepwise) showed that the practical post-operative IOP value was the main predictor of the theoretical post-operative NCT-IOP, IOPcc and IOPg values (all P values <0.001). The postoperative applanation time 1 (AT1) value (B = 8.079, t = 4.866, P < 0.001), preoperative central corneal thickness (CCT) value (B = 0.035, t = 2.732, P = 0.014) and postoperative peak distance (PD) value (B = 0.515, t = 2.176, P = 0.043) were the main predictors of the theoretical post-operative CST-IOP value. CONCLUSIONS IOP values are underestimated when assessed after SMILE by using NCT-IOP, IOPg and CST-IOP. The practical postoperative IOPcc value and theoretical post-operative CST-IOP value may be more preferable for IOP assessment in the early phase after SMILE. TRIAL REGISTRATION Current Controlled Trials ChiCTRONRC13003114 . Retrospectively registered 17 March 2013.
منابع مشابه
Evaluation of Corneal Biomechanical Properties Modification after Small Incision Lenticule Extraction Using Scheimpflug-Based Noncontact Tonometer
PURPOSE To quantify the effect of small incision lenticule extraction (SMILE) on the corneal biomechanics using Scheimpflug noncontact tonometer (Corvis ST). METHODS Twenty eyes of twenty patients, evaluated as eligible for surgery, with high myopia and/or moderate myopic astigmatism, underwent small incision lenticule extraction (SMILE). All patients underwent Corvis ST preoperatively and po...
متن کاملComparison of different intraocular pressure measurement techniques in normal eyes and post small incision lenticule extraction
PURPOSE The purpose of the study was to determine the accuracy of intraocular pressure (IOP) measurement after small incision lenticule extraction (SMILE) using Goldmann applanation tonometry (GAT) and ocular response analyzer (ORA). METHODS This is a prospective clinical study that was conducted on 30 eyes in the interval between February 2016 and September 2016. The age of the patients rang...
متن کاملCorneal biomechanical changes in eyes with small incision lenticule extraction and laser assisted in situ keratomileusis
BACKGROUND Evaluating the corneal biomechanical changes using the Ocular Response Analyzer and the Corvis ST in eyes with incision lenticule extraction (SMILE) and laser assisted in situ keratomileusis (LASIK). METHODS This is a retrospective study that included 50 eyes equally divided into two groups. The first group included eyes that underwent SMILE procedure using VisuMax® 500 kHz laser s...
متن کاملChanges in Corneal Deformation Parameters after Lenticule Creation and Extraction during Small Incision Lenticule Extraction (SMILE) Procedure
PURPOSE To investigate the effects of lenticule creation and subsequent corneal lenticule extraction on corneal deformation parameters during small incision lenticule extraction (SMILE) procedure. MATERIALS AND METHODS In this prospective study, 18 eyes of 10 patients (27.90 ± 7.11 years, -5.64 ± 2.45 diopters) scheduled for SMILE procedure were enrolled. Changes in the corneal deformation pa...
متن کاملComparison of current tonometry techniques in measurement of intraocular pressure
PURPOSE To compare four tonometry techniques: Goldmann applanation tonometer (GAT), Dynamic contour tonometer (DCT), Non-contact tonometer (NCT), and Ocular Response Analyzer (ORA) in the measurement of intraocular pressure (IOP) and the impact of some corneal biomechanical factors on their performance. METHODS In this cross-sectional study, volunteers with normal ophthalmic examination and n...