System for simultaneous measurements of bilaterally symmetrical acupoints multifrequency impedances
نویسندگان
چکیده
Devices which can obtain comparable bilaterally symmetrical acupoints (BSA) multifrequency impedances (MFI) are often needed in the detection of the energy balance states of acupoints in traditional Chinese medicine. To satisfy these needs, a two-channel impedance measurement system has been introduced which is capable of accurately and simultaneously measuring BSA MFI. The system includes a set of five electrodes, two of which are injected with exciting current signal to synchronously and equally excite BSA; the other three electrodes are used as sensors to simultaneously sense the response signal from both sides. The system also includes a PC-based time-domain signal testing platform with arbitrary current waveform generation and three channels (one exciting current and two response voltages) simultaneously sampling, and a set of MFI simultaneously unbiased computing algorithms based on special odd multisine current signal input. Preliminary validating experiments suggest that the system allows accurate and synchronous measurement of BSA MFI at least in the frequency range of 10 Hz to 60 kHz, and the obtained BSA MFI are well comparable.
منابع مشابه
Multifrequency simultaneous bioimpedance measurements using multitone burst signals for dynamic tissue characterization. B.Sanchez and R.Bragos
In this paper we present the keypoints to perform multifrequency simultaneous bioimpedance measurements using multitone signals. Concerning the frequency distribution, tones are spread over 1kHz to 1MHz range using a custom frequency distribution which we called Bilateral Quasi Logarithmic (BQL). BQL concentrates a higher number of tones around the impedance relaxation and contains a frequency ...
متن کاملOptimal Current Meter Placement for Accurate Fault Location Purpose using Dynamic Time Warping
This paper presents a fault location technique for transmission lines with minimum current measurement. This algorithm investigates proper current ratios for fault location problem based on thevenin theory in faulty power networks and calculation of short circuit currents in each branch. These current ratios are extracted regarding lowest sensitivity on thevenin impedance variations of the netw...
متن کاملAn Efficient Hierarchical Modulation based Orthogonal Frequency Division Multiplexing Transmission Scheme for Digital Video Broadcasting
Due to the increase of users the efficient usage of spectrum plays an important role in digital terrestrial television networks. In digital video broadcasting, local and global content are transmitted by single frequency network and multifrequency network respectively. Multifrequency network support transmission of global content and it consumes large spectrum. Similarly local content are well ...
متن کاملSystem Identification Algorithm Analysis of Acupuncture Effect on Mean Blood Flux of Contralateral Hegu Acupoint
Background. Acupoints (belonging to 12 meridians) which have the same names are symmetrically distributed on the body. It has been proved that acupoints have certain biological specificities different from the normal parts of the body. However, there is little evidence that acupoints which have the same name and are located bilaterally and symmetrically have lateralized specificity. Thus, resea...
متن کاملA Novel Multi-way Power Divider Design with Arbitrary Complex Terminated Impedances
A simple and analytical design methodology for a novel multi-way Bagley Polygon power divider with arbitrary complex terminated impedances is proposed in this paper. The design parameters including electrical lengths and characteristic impedances can be obtained by the provided closed-form mathematical expressions when complex terminated impedances are known. Moreover, for convenient test, we d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 6 شماره
صفحات -
تاریخ انتشار 2013