Regularized iterative reconstruction for undersampled BLADE and its applications in three-point Dixon water-fat separation.
نویسندگان
چکیده
In MRI, the suppression of fat signal is very important for many applications. Multipoint Dixon based water-fat separation methods are commonly used due to its robustness to B(0) homogeneity compared with other fat suppression methods, such as spectral fat saturation. The traditional Cartesian k-space trajectory based multipoint Dixon technique is sensitive to motion, such as pulsatile blood flow, resulting in artifacts that compromise image quality. This work presents a three-point Dixon water-fat separation method using undersampled BLADE (aka PROPELLER) for motion robustness and speed. A regularized iterative reconstruction method is then proposed for reducing the streaking artifacts coming from undersampling. In this study, the performance of the regularized iterative reconstruction method is first tested by simulations and on MR phantoms. The performance of the proposed technique is then evaluated in vivo by comparing it with conventional fat suppression methods on the human brain and knee. Experiments show that the presented method delivers reliable water-fat separation results. The reconstruction method suppresses streaking artifacts typical for undersampled BLADE acquisition schemes without missing fine structures in the image.
منابع مشابه
Water Fat Separation with Undersampled TSE BLADE Based on Three Point Dixon
Introduction In the three-point Dixon water fat separation method, one in-phase echo and two out-of-phase echoes are sampled in Cartesian k-space trajectory conventionally [1][2]. The Cartesian sampling is sensitive to motions, such as from pulsation and flow, which cause artifacts degrading the image quality. To address this problem, a non Cartesian sampling method, TSE BLADE three-point Dixon...
متن کاملWater-fat separation with parallel imaging based on BLADE.
Uniform suppression of fat signal is desired in clinical applications. Based on phase differences introduced by different chemical shift frequencies, Dixon method and its variations are used as alternatives of fat saturation methods, which are sensitive to B0 inhomogeneities. Iterative Decomposition of water and fat with Echo Asymmetry and Least squares estimation (IDEAL) separates water and fa...
متن کاملCS-Dixon: Compressed Sensing for Water-Fat Dixon Reconstruction
Introduction: Water-fat separation is of interest in several MRI applications including fat suppression and fat quantification. Chemical shift imaging allows robust water-fat separation [1, 2], however the acquisition of multiple images results in prolonged scan time. Accelerated water-fat separation using compressed sensing (CS) was partly addressed in [3] by considering the separation as a sp...
متن کاملCompressed sensing for chemical shift-based water-fat separation.
Multi echo chemical shift-based water-fat separation methods allow for uniform fat suppression in the presence of main field inhomogeneities. However, these methods require additional scan time for chemical shift encoding. This work presents a method for water-fat separation from undersampled data (CS-WF), which combines compressed sensing and chemical shift-based water-fat separation. Undersam...
متن کاملMulticoil Dixon chemical species separation with an iterative least-squares estimation method.
This work describes a new approach to multipoint Dixon fat-water separation that is amenable to pulse sequences that require short echo time (TE) increments, such as steady-state free precession (SSFP) and fast spin-echo (FSE) imaging. Using an iterative linear least-squares method that decomposes water and fat images from source images acquired at short TE increments, images with a high signal...
متن کاملذخیره در منابع من