We evaluated the enzymic mechanism by which 3-keto butylidene-beta-2-chloro-4-nitrophenyl maltopentaoside (3KB-G5-CNP) serves as a substrate for serum pancreatic (p-) and salivary (s-) amylases. In aliquots of the reaction mixture, three kinds of beta-2-chloro-4-nitrophenyl oligosaccharides (glucose, maltoside, and maltotrioside) were separated from the substrate by high-performance liquid chromatography. Both isoenzymes behaved nearly identically and produced almost the same products. We automated a double kinetic procedure for determining total (t-) and p-amylase with use of a selective inhibitor from wheat germ in a single channel on the Hitachi 7050 analyzer. Within- and between-run CVs were, respectively, 0.5% and 1.7% for t-amylase (240 U/L), and 0.7% and 2.3% for p-amylase (230 U/L). The test results varied linearly with concentrations up to approximately 2000 U/L for t- and p-amylase activities. p/s ratios varied from 0.2 to 5.0. Results correlated well with those obtained by the monoclonal inhibition method (r = 0.992).
منابع مشابه
Catalytic concentrations of amylase isoenzymes: an assay with wheat-germ inhibitor and 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate.
We coupled a kinetic procedure to a selective inhibiting method for determining amylase isoenzymes in biological samples, using 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate and a wheat-germ selective inhibitor with the Gilford S-III spectrophotometer. On plotting remaining amylase activities/total amylase activities (R/T) vs pancreatic amylase activities/salivary a...
متن کاملAutomated measurement of amylase isoenzymes with 4-nitrophenyl-maltoheptaoside as substrate and use of a selective amylase inhibitor.
We automated a kinetic procedure for determining amylase isoenzymes in serum and urine samples. We used 4-nitro-phenylmaltoheptaoside as substrate and a selective amylase inhibitor with the Abbott-VP bichromatic system. By use of the maximum differences between pancreatic (P) and salivary (S) amylase activities remaining after inhibition by the selective inhibitor and by use of the linear range...
متن کاملMethods compared for determining total amylase activity and amylase isoenzymes in serum.
We evaluated two kinetic methods for determining total amylase activity and isoenzyme composition in serum. Stability studies of reagents for measuring total activity indicate that reagents containing 4-nitrophenyl-alpha-glucosides or enzyme-linked reagents can be stored only for seven days at 4 degrees C. Methods based on 4-nitrophenyl-alpha-glucoside substrates cannot be used if the reagent a...
متن کاملEnzymatic method for assaying calcium in serum and urine with porcine pancreatic alpha-amylase.
We developed a kinetic assay for calcium in serum and urine, based on the activation of porcine pancreatic alpha-amylase (EC 3.2.1.1) with 2-chloro-4-nitrophenyl-alpha-maltotrioside as substrate. The kinetic generation of 2-chloro-4-nitrophenol, monitored at 405 nm, was proportional to the concentration of calcium in serum and urine. The assay was developed and evaluated with the Cobas Bio cent...
متن کاملAssay of pancreatic amylase with use of monoclonal antibodies evaluated.
To evaluate a new method for measuring pancreatic amylase in serum, in which the salivary isoenzyme is inhibited with a specific monoclonal antibody, we determined the activity of pancreatic and salivary amylase in sera from 103 healthy subjects and from 114 hospitalized patients having a wide range of total amylase activities. CVs for the proposed method ranged from 0.8% to 5.1% (within day) a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 37 8 شماره
صفحات -
تاریخ انتشار 1991