Defects in diagnostic kits for determination of urate in serum.

نویسندگان

  • T P Whitehead
  • E A Bevan
  • L Miano
  • A Leonardi
چکیده

Certain diagnostic kits that measure serum urate by the Barham and Trinder principle of enzymic liberation of oxygen and its combination with chromogens can give results for urate in fresh serum that are approximately 20% lower than results from serum stored at ambient temperature for 72 h. In fresh serum, antioxidants compete with chromogen for liberated peroxyl-oxygen. We postulate that during storage the interfering antioxidant substances are destroyed. In some diagnostic kits, L-ascorbate oxidase is added to the reaction, eliminating some but not all of this effect. We discuss defects of several commercially available kits for determination of serum urate and recommend comparing results of these kits with results from the phosphotungstic acid method as a precaution against falsely low results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Positive interference in Radioimmunoassay determination of serum total T3

Introduction: Determination of thyrotropin, total and free thyroxine and triiodothyronine are widely used as diagnostic methods for thyroid function evaluation. There have been numerous reports of interferences in thyroid hormone immunoassays. Herein, a prominent positive interference is reported for a radioimmunoassay kit of total triiodothyronine. Materials and Methods: In this study, a total...

متن کامل

طراحی کیت اندازه‌گیری IgE اختصاصی آلرژن‌های شیر گاو به‌روش الایزا

Background: The hypersensitivity to cow’s milk allergens is the most common allergies in children at the first year of life. The specific IgE evaluation is one of the important methods in diagnosis of allergic disease. The aim of this study was development of a sensitive and credible procedure for detection of cow’s milk allergens specific IgE. Methods: The allergen discs...

متن کامل

ارزیابی بین آزمایشگاهی و بین کیتی آزمون الایزا برای تشخیص آنتی بادی های IgG اختصاصی علیه توکسوپلاسما گوندی ای

Background and purpose: Toxoplasmosis is a parasitic protozoan disease producing severe complications in congenital and immunocompromised cases. The enzyme-linked immunosorbent assay (ËLÏSÂ) is the most common laboratory method for serodiagnosis of toxoplasmosis. Çommercial kits have no unique procedure for standardization and this may influence the consistency of the results. The present stu...

متن کامل

Qualitative and Quantitative Approaches for Determination of Hemolyzed Serum

Abstract Background and Objective: Prevention of medical laboratory errors is a major goal of quality control programs. Hemolyzed specimen is one of the common issues causing medical laboratory errors. Apart from the visual assessment, the measurement of serum hemoglobin concentration can be another method to evaluate the intensity of hemolysis. We aimed to assess hemolyzed serum s...

متن کامل

Studies on Interrelation of Vitamin A Deficiency and Bladder Stones Formation

Serum Vitamin A, total protein, serum electrophoresis, were determined in pediatric patients with urolithiasis (mostly bladder stones) and compared to that of normal healthy volunteers. The level of Vitamin A in healthy volunteers was found to be significantly (P<0.001) higher than that of patients with urolithiasis. The amount of total serum protein, how­ever, was not significantly different i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 37 6  شماره 

صفحات  -

تاریخ انتشار 1991