Biodegradable polymer drug-eluting stents versus first-generation durable polymer drug-eluting stents

نویسندگان

  • Pravesh Kumar Bundhun
  • Manish Pursun
  • Feng Huang
چکیده

BACKGROUND Even if drug-eluting stents (DES) showed beneficial effects in patients with coronary artery diseases (CADs), limitations have been observed with the first-generation durable polymer DES (DP-DES). Recently, biodegradable polymer DES (BP-DES) have been approved to be used as an alternative to DP-DES, with potential benefits. We aimed to systematically compare BP-DES with the first-generation DP-DES using a large number of randomized patients. METHODS Electronic databases were searched for randomized controlled trials (RCTs) comparing BP-DES with first-generation DP-DES. The main endpoints were the long-term (≥2 years) adverse clinical outcomes that were reported with these 2 types of DES. We calculated odds ratios (ORs) with 95% confidence intervals (CIs) and the analysis was carried out by RevMan 5.3 software. RESULTS Twelve trials with a total number of 13,480 patients (7730 and 5750 patients were treated by BP-DES and first-generation DP-DES, respectively) were included. During a long-term follow-up period of ≥2 years, mortality, myocardial infarction (MI), target lesion revascularization (TLR), and major adverse cardiac events (MACEs) were not significantly different between these 2 groups with OR: 0.84, 95% CI: 0.66-1.07; P = .16, I = 0%, OR: 1.01, 95% CI: 0.45-2.27; P = .98, I = 0%, OR: 0.91, 95% CI: 0.75-1.11; P = .37, I = 0% and OR: 0.86, 95% CI: 0.44-1.67; P = .65, I = 0%, respectively. Long-term total stent thrombosis (ST), definite ST, and probable ST were also not significantly different between BP-DES and the first-generation DP-DES with OR: 0.77, 95% CI: 0.50-1.18; P = .22, I = 0%, OR: 0.71, 95% CI: 0.43-1.18; P = .19, I = 0% and OR: 1.31, 95% CI: 0.56-3.08; P = .53, I = 6%, respectively. CONCLUSION Long-term mortality, MI, TLR, MACEs, and ST were not significantly different between BP-DES and the first-generation DP-DES. However, the follow-up period was restricted to only 3 years in this analysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis

OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...

متن کامل

Baremetal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis OPEN ACCESS

Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food a...

متن کامل

Efficacy and Safety of Biodegradable Polymer Biolimus-Eluting Stents versus Durable Polymer Drug-Eluting Stents: A Meta-Analysis

BACKGROUNDS Drug-eluting stents (DES) with biodegradable polymers have been developed to address the risk of thrombosis associated with first-generation DES. We aimed to determine the efficacy and safety of biodegradable polymer biolimus-eluting stents (BES) versus durable polymer DES. METHODS Systematic database searches of MEDLINE (1950 to June 2013), EMBASE (1966 to June 2013), the Cochran...

متن کامل

Two-year outcome of a randomized trial comparing second-generation drug-eluting stents using biodegradable or durable polymer.

Two-Year Outcome of a Randomized Trial Comparing Second-Generation Drug-Eluting Stents Using Biodegradable or Durable Polymer Recentnetworkmeta-analyseshave raisedconcerns about the safety of biodegradable polymerdrug-eluting stents (BP-DES) compared with durable polymer everolimus-eluting stents (DP-EES).1-3 The NOBORI Biolimus-Eluting vs XIENCE/ PROMUSEverolimus-ElutingStentTrial (NEXT) is a9...

متن کامل

Comparison of biolimus eluted from an erodible stent coating with bare metal stents in acute ST-elevation myocardial infarction (COMFORTABLE AMI trial): rationale and design.

AIMS Compared with bare metal stents (BMS), early generation drug-eluting stents (DES) reduce the risk of revascularisation in patients with ST-elevation myocardial infarction (STEMI) at the expense of an increased risk of very late stent thrombosis (ST). Durable polymer coatings for controlled drug release have been identified as a potential trigger for these late adverse events and this has l...

متن کامل

Ultrathin strut biodegradable polymer sirolimus-eluting stent versus durable polymer everolimus-eluting stent for percutaneous coronary revascularisation (BIOSCIENCE): a randomised, single-blind, non-inferiority trial.

BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 96  شماره 

صفحات  -

تاریخ انتشار 2017