An Improved Design of the Spiral-Coil EMAT for Enhancing the Signal Amplitude

نویسندگان

  • Xiaojuan Jia
  • Qi Ouyang
  • Xinglan Zhang
چکیده

The low energy transition efficiency of electromagnetic ultrasonic transducer (EMAT) is a common problem in practical application. For the purpose of enhancing the amplitude of the received signal, an improved double-coil bulk wave EMAT is proposed for the thickness measurement of metallic block. This new configuration of magnets consists of a solid cylindrical magnet and a ring-shaped magnet encircling the outer side of the solid cylindrical one. A double-coil was applied instead of a single spiral-coil. Numerical simulations were performed to analyze and optimize the proposed configuration of the EMAT by the 2-D axisymmetric finite element model (FEM). The experiment effectively verifies the rationality of the new configuration and the feasibility of improving the signal strength.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Optimization of Lamb and Rayleigh Wave Generation Using Wideband-low-frequency Emats

This paper describes a non-contact ElectroMagnetic Acoustic Transducer (EMAT) that can be used to generate both Lamb and Rayleigh waves on metal samples. The generated waves are wideband and low frequency with a dominant frequency content centred on approximately 200kHz extending to around 500kHz. Detection of the waves is achieved using a linear coil detection EMAT. The transducers (generator ...

متن کامل

Enhancement of signal amplitude of surface wave EMATs based on 3-D simulation analysis and orthogonal test method

The amplitude of an ultrasonic signal generated by electromagnetic acoustic transducers (EMATs) is typically low when compared to those generated by contacting transducers, which restricts the application of EMATs in the fields of nondestructive testing and nondestructive evaluation. The transmission process of a surface wave EMAT is studied, based on a previously established 3-D model, with th...

متن کامل

Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance

Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...

متن کامل

Application of Pulse Compression Signal Processing Techniques to Electromagnetic Acoustic Transducers (emats) for Non-contact Thickness Measurements and Imaging

A pair of non-contact EMATs has been used for thickness measurements and imaging of metallic plates. This was performed using wide bandwidth EMATs and pulsecompression signal processing techniques, using chirp excitation. This gives a greatly improved Signal to Noise Ratio (SNR) for non-contact experiments, increasing the speed of data acquisition. A numerical simulation of the technique has co...

متن کامل

A New Omni-Directional EMAT for Ultrasonic Lamb Wave Tomography Imaging of Metallic Plate Defects

This paper proposes a new omni-directional electromagnetic acoustic transducer (EMAT) for the ultrasonic Lamb wave (ULW) tomography imaging (TI) of defects in metallic plates. The proposed EMAT is composed of a permanent magnet and a coil with a contra-flexure structure. This new EMAT coil structure is used for omni-directional ULW transmission and reception and ULW TI for the first time. The t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017