On possible extensions of X-ray crystallography through diffraction-pattern oversampling

نویسندگان

  • Miao
  • Sayre
چکیده

It is known that sampling the diffraction pattern of a finite specimen, at a spacing somewhat finer than the Nyquist spacing (the inverse of the size of the diffracting specimen), corresponds to generating a no-density region surrounding the electron density of the specimen. This no-density region can then be used to retrieve the phase information. In earlier papers [Miao, Sayre & Chapman (1998). J. Opt. Soc. Am. A15, 1662-1669; Sayre, Chapman & Miao (1998). Acta Cryst. A54, 232-239], it was demonstrated, in the case of non-crystalline specimens, that this no-density region could be used to retrieve the phase information; here the same is performed for crystalline and near-crystalline specimens. By employment of an iterative algorithm, the phase information could be recovered from computer-generated oversampled diffraction patterns of small specimens that are (a) perfect or imperfect crystals, or (b) have a repeated motif without orientational regularity, or (c) are an unrepeated motif, such as an amorphous glass, a single molecule or a single biological cell. Cases (a) and (b) represent an extension over work recently published [Miao, Charalambous, Kirz & Sayre (1999). Nature (London), 400, 342-344]. Our algorithm requires an approximate envelope for the specimen. It does not require any structural knowledge concerning the specimen and does not require data to atomic resolution (although it can use such data if present). After a few hundred to a few thousand iterations, the correct phase set and image are recovered. The oversampling technique thus greatly extends the specimen range of X-ray crystallography but it imposes a high radiation dose on the specimens compared with the situation in crystallography, in which it is usual for the pattern to be sampled at the (much less fine) Bragg spacing (the inverse of the size of the unit cell). In cases where the specimen is a crystal, there are also possibilities for oversampling relative to Bragg (instead of Nyquist) sampling, thus providing a lesser degree of oversampling and the possibility of lower dosage. Damage of the specimen in consequence of the dose will in many cases seriously affect the quality and resolution of the imaging, but in at least one case [the biological cell in (c) above] the imaging obtainable with the aid of a cryogenic protective technique should surpass any other present method of whole-cell imaging. In addition, with the possible appearance in the future of free electron lasers (>10(12) photons and <200 fs per pulse), it is possible to circumvent the radiation-damage problem by recording diffraction patterns before damage manifests itself.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extending The Methodology Of X-ray Crystallography To Allow X-ray Microscopy Without X-ray Optics

We demonstrate that the soft X-ray diffraction pattern from a micron-size noncrystalline specimen can be recorded and inverted to form a high-resolution image. The phase problem is overcome by oversampling the diffraction pattern. The image is obtained using an iterative algorithm. The technique provides a method for X-ray microscopy requiring no highresolution X-ray optical elements or detecto...

متن کامل

Extending the Methodology of X-ray Crystallography to Non-Crystalline Specimens

Since the emergence of powerful X-ray sources such as synchrotron radiation, the area of X-ray structure determination gradually evolved into two fields. The relatively small one is X-ray Microscopy which employs X-ray lenses such as zone plates, compound refractive lenses, curved mirrors and glass capillaries to focus X-rays to determine the structures of non-crystalline specimens. The resolut...

متن کامل

The oversampling phasing method.

Sampling the diffraction pattern of a finite specimen more finely than the Nyquist frequency (the inverse of the size of the diffracting specimen) corresponds to surrounding the electron density of the specimen with a no-density region. When the no-density region is bigger than the electron-density region, sufficient information is recorded so that the phase information can be retrieved from th...

متن کامل

Taking X-ray diffraction to the limit: macromolecular structures from femtosecond X-ray pulses and diffraction microscopy of cells with synchrotron radiation.

Recent work is extending the methodology of X-ray crystallography to the structure determination of noncrystalline specimens. The phase problem is solved using the oversampling method, which takes advantage of "continuous" diffraction patterns from noncrystalline specimens. Here we review the principle of this newly developed technique and discuss the ongoing experiments of imaging nonperiodic ...

متن کامل

Reconstruction of the shapes of gold nanocrystals using coherent x-ray diffraction.

Inverse problems arise frequently in physics: The magnitude of the Fourier transform of some function is measurable, but not its phase. The "phase problem" in crystallography arises because the number of discrete measurements (Bragg peak intensities) is only half the number of unknowns (electron density points in space). Sayre first proposed that oversampling of diffraction data should allow a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Acta crystallographica. Section A, Foundations of crystallography

دوره 56 (Pt 6)  شماره 

صفحات  -

تاریخ انتشار 2000