Sampling frequency affects the processing of ActiGraph 1 raw acceleration data to activity counts

نویسنده

  • Daniel Arvidsson
چکیده

([email protected])1,2* 4 1Center for Research in Childhood Health, Department of Sports Science and Clinical 5 Biomechanics, University of Southern Denmark, Denmark 6 2Unit for Clinical Physiology and Nuclear Medicine, Department of Translational 7 Medicine, Lund University, Sweden 8 9 *Daniel Arvidsson (corresponding author) 10 Center for Research in Childhood Health, Department of Sports Science and Clinical 11 Biomechanics, University of Southern Denmark 12 Campusvej 55, 5230 Odense, Denmark. 13 Phone: +45 26 33 50 20 14 E-mail: [email protected] 15 16 17 18 19 20 21 22 23 24 Articles in PresS. J Appl Physiol (December 3, 2015). doi:10.1152/japplphysiol.00628.2015

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sampling frequency affects the processing of Actigraph raw acceleration data to activity counts.

ActiGraph acceleration data are processed through several steps (including band-pass filtering to attenuate unwanted signal frequencies) to generate the activity counts commonly used in physical activity research. We performed three experiments to investigate the effect of sampling frequency on the generation of activity counts. Ideal acceleration signals were produced in the MATLAB software. T...

متن کامل

Exploring the ActiLife(®) filtration algorithm: converting raw acceleration data to counts.

Though portable accelerometers are ubiquitous in physiology and public health studies, their accuracy as objective measures of physical activity is still being examined. This paper enumerates and analyzes the various biases of the widely used ActiLife(®) software in reporting activity counts from ActiGraph(®) accelerometers. In particular, we focus on the two-stage proprietary filtration algori...

متن کامل

Biomechanical examination of the 'plateau phenomenon' in ActiGraph vertical activity counts.

This paper determines if the leveling off ('plateau/inverted-U' phenomenon) of vertical ActiGraph activity counts during running at higher speeds is attributable to the monitor's signal filtering and acceleration detection characteristics. Ten endurance-trained male participants (mean (SD) age = 28.2 (4.7) years) walked at 3, 5 and 7 km h(-1), and ran at 8, 10, 12, 14, 16, 18 and 20 km h(-1) on...

متن کامل

Comparison of Raw Acceleration from the GENEA and ActiGraph™ GT3X+ Activity Monitors

PURPOSE To compare raw acceleration output of the ActiGraph™ GT3X+ and GENEA activity monitors. METHODS A GT3X+ and GENEA were oscillated in an orbital shaker at frequencies ranging from 0.7 to 4.0 Hz (ten 2-min trials/frequency) on a fixed radius of 5.08 cm. Additionally, 10 participants (age = 23.8 ± 5.4 years) wore the GT3X+ and GENEA on the dominant wrist and performed treadmill walking (...

متن کامل

Accelerometer counts and raw acceleration output in relation to mechanical loading.

The purpose of this study was to assess the relationship of accelerometer output, in counts (ActiGraph GT1M) and as raw accelerations (ActiGraph GT3X+ and GENEA), with ground reaction force (GRF) in adults. Ten participants (age: 29.4 ± 8.2 yr, mass: 74.3 ± 9.8 kg, height: 1.76 ± 0.09 m) performed eight trials each of: slow walking, brisk walking, slow running, faster running and box drops. GRF...

متن کامل